Vimar ELVOX ECG3 Manual Para El Conexionado Y El Uso página 25

Tarjeta para mando de persianas o toldos
Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 58
If the safety device engages while closing, the movement will reverse and reopen.
If the opening / closing safety input is engaged, opening and closing will not be possible.
If the opening / closing safety input is engaged during the travel, there will be a brief reversal of direction.
The opening / closing safety input only supports N.C. contacts.
System type:
Photocells
It is absolutely necessary for there to be electromechanical limit switches that stop the motor
7.2 Rolling shutters with manned operation
Operation in "manned" mode requires a visual check on the movement of the rolling shutter.
To open or close the rolling shutter, press one of the wall buttons for more than half a second to control the movement, releasing the button will
cause the system to stop immediately.
The saved remote controls are not active in "manned" mode. N.B.: The opening / closing safety input only supports N.C. contacts.
, if not used, it is necessary to jumper input IN3 with the COM terminal.
EN
All manuals and user guides at all-guides.com
Open
Closed
Push-button
23
Tabla de contenido
loading

Tabla de contenido