LED indicators: The two-colour LED DL1 is off while the blue LED DL2 is on steady during normal operation; as soon as one or more sensors exceed the set threshold there
will be a sequence of flashing light signals.
Threshold
RED LED
Sun
off
Wind
blink
Rain
off
GREEN
5.1 Locking movement (DIP switch sw1 ON sw2 OFF)
If you wish to lock the awning in a certain position and prevent it from opening or closing under the action of the sun sensor, simply press the control button a second
time before the awning completes its travel.
5.2 Unlocking movement (DIP switch sw1 ON sw2 OFF)
To return to normal automatic operation and re-enable the light sensor, simply command opening or closing via the remote control - wall button and let the work
time end (90 sec.).
NB: With DIP switches sw1 and sw2 OFF you can stop the movement of the awning by pressing the button during the movement, the light sensor will
not be disabled.
5.3 Activation and work times with awning operation
Description
Work time
Delay time on light sensor tripping
Wind sensor delay time
Rain sensor delay time
6. Wiring with rolling shutter operation (DIP-switch 1 OFF and DIP-switch 2 ON)
6.1 Connecting mains power supply and electric motor power supply
Common
Closed
Open
EN
All manuals and user guides at all-guides.com
DL1
GREEN LED
blink
off
off
RED
BLUE
Time value
90 sec.
60 sec.
5 sec.
5 sec.
DL2
BLUE LED
on
on
blink