Operating manual
• Press the test button (test one or two batteries depending on the batteries connected).
- Green indicator light: battery charged (> 12.8 V). Start-up is possible.
- Orange indicator light: battery is partially charged (voltage between 12.4 -12.8 V). We strongly rec-
ommend recharging the batteries before using the machine. However, it is possible to start a vehicle.
• Red indicator light: battery is discharged (voltage < 12.4 V). Unable to start.
• No indicator light: Battery very deeply discharged or no battery is detected (< 4 V). Unable to start.
The test is only valid if the battery (or batteries) has been idle for at least 15 minutes.
STARTER FUNCTION
12 V Mode
For starting with 12 V, only one battery can be fitted to the trolley. In this case, the one battery
must be positioned on the right side (when viewed from behind) in order to be connected to
the device's negative (-) terminal.
• Unplug the mains lead (battery charged beforehand).
• Set the battery switch to the 'OFF' position.
• Connect the cables to the ENERGY STATION FP's 12 V output (red cable to the 12 V outlet,
12V
black cable to the battery's negative [-] terminal).
BATTERY 2
• Connect the red clamp to the battery's positive (+) terminal and the black clamp to the
negative (-) terminal (if the polarity is reversed, this will be indicated by the Energy Station; a
warning buzzer will sound and the red LED indicator light will light up
ON
• Switch the battery switch to the 'ON' position.
• Go to the vehicle control station and turn the ignition key. If the engine will not start, wait
three minutes between each start-up attempt (each start-up attempt should last no longer
than six seconds max.).
- If the recommended time between each test is not respected (3 minutes) or if the test time is
6
3
too long (> 6 seconds), the likelihood of starting the vehicle is reduced (risk of power loss).
s
STOP
max
min
- There is a risk of acid leakage and damage to the internal battery if the recommended times
are not observed.
- If the vehicle still does not start, there may be a problem other than a bad battery: a faulty
alternator or glow plug, etc.
• Switch the battery switch to the 'OFF' position.
• Recharge the batteries after use (see charger section).
+