1. GENERAL
1.1 General terms of delivery
Any equipment, even CARRIAGE and PACKING FREE, travels at the consignee's risk. The consignee
shall make reserves in writing on the carrier's delivery bill if he notes damage caused during the
transport (confirmation to be sent to the carrier within 48 hours by registered mail and Acknowledgement
of Receipt).
1.2 Water treatment
In order to use our appliances in the best conditions, swimming pool water shall comply with the
following values: free chlorine: max. 2.5 mg/L, total bromine: max. 5.5 mg/L, pH between 6.9 and 8.0.
For any other treatment, the fitter and the user shall apply to the supplier of the planned disinfection's
process (chemical, electrochemical or electro-physical) for the compatibility with the materials of our
appliances. In any case, treatment shall be installed downstream the heating equipment.
2. DESCRIPTION
2.1 Presentation
Heatline 20 end 40 kW
Heatline 70 kW
2.2 Dimensions
Heatline 20 and 40 KW : A = 535 mm, B = 198 mm
Heatline 70 KW : A = 665 mm, B = 328 mm
multitubular titanium or inox heat
exchanger
fittings ½ union PVC Ø63 +
reduction Ø50
male heating fitting Ø26/34
two bolts and four M6 inserts for
fixing the body
drain plug for primary circuit
(Ø15/21)
injected thimble (for introducing a
regulation sensor) Ø11 inside
plug Ø15/21 (possible location for
raising the flow controller to Ø20/27)
orifice blocked (with threading Ø
26/34 female) on exchanger body 70
kW: never use a primary circuit
connection!
check valve (female connection
Ø26/34 not part of the original
assembly)
nipple (male/male Ø26/34, not part
of the original assembly)
B
120
A
2
Dimensions with ± 1mm