Mounting the auxiliary handle
(figure 4).
Screw in and firmly tighten the auxiliary handle.
Filling the coolant container
(figure 5).
Prevent the flow of liquid
WARNING
along the cable into the
socket outlet or into the core drill unit, as this
can lead to electric shock. Tie a bow in the
cable near the plug, so that any liquid can drip
off.
Unscrew the cap from the coolant container.
Fill with water soluble cutting fluid like Slug-
ger Cutting Fluid.
Replace the cap back onto the coolant con-
tainer.
Do not use the magnetic core drill unit when
the cooling-lubricant system is defective. Each
time before operating, check for tightness
against leaks and for cracks in the hoses. Pre-
vent liquids from entering or penetrating elec-
trical components.
Auxiliary handle
Coolant container