Technical Specifications - voestalpine Böhler TERRA 320 MSE Instrucciones De Uso

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 60

7 TECHNICAL SPECIFICATIONS

Power supply voltage U1 (50/60Hz)
*
Zmax (@PCC)
Slow blow line fuse
Communication bus
Maximum input power (kVA)
Maximum input power (kW)
Power factor PF
Efficiency (µ)
Cos
Max. input current I1max
Effective current I1eff
MMA duty factor (40°C)
(x=50%)
(x=60%)
(x=100%)
MMA duty factor (25°C)
(x=80%)
(x=100%)
MIG/MAG duty factor (40°C)
(x=50%)
(x=60%)
(x=100%)
MIG/MAG duty factor (25°C)
(x=80%)
(x=90%)
(x=100%)
Adjustment range I2
MMA open circuit voltage Uo
MIG/MAG open circuit voltage Uo
IP Protection rating
Insulation class
Dimensions (lxdxh)
Weight
Manufacturing Standards
Power supply cable
Length of power supply cable
TERRA 320 MSE
*
This equipment complies with EN/IEC 61000-3-11.
*
This equipment does not comply with EN/IEC 61000-3-12. If it is connected to a public low voltage system, it is the responsibility of the
installer or user of the equipment to ensure, by consultation with the distribution network operator if necessary, that the equipment may be
connected. (Consult the "Electromagnetic fields & interferences" - " EMC equipment classification in accordance with EN/IEC 60974-10" section).
TERRA 400-500 MSE
*
This equipment complies with EN/IEC 61000-3-11 if the maximum permissible mains impedance at the interface point to the public grid
(point of common coupling, PCC) is smaller than or equal to the Zmax stated value. If it is connected to a public low voltage system, it is
the responsibility of the installer or user of the equipment to ensure, by consultation with the distribution network operator if necessary, that the
equipment may be connected.
*
This equipment does not comply with EN/IEC 61000-3-12. If it is connected to a public low voltage system, it is the responsibility of the
installer or user of the equipment to ensure, by consultation with the distribution network operator if necessary, that the equipment may be
connected. (Consult the "Electromagnetic fields & interferences" - " EMC equipment classification in accordance with EN/IEC 60974-10" section).
30
TERRA 320 MSE
3x400V±15%
-
25A
DIGITAL
16.2kVA
10.9kW
0.68
88%
0.99
23.2A
16.5A
300A
290A
250A
300A
290A
320A
310A
260A
/
320A
310A
3÷320A
61Vdc
61Vdc
IP23S
H
620x240x460mm
20.2kg.
EN 60974-1/EN 60974-10
4x2.5mm2
5m
TERRA 400 MSE
3x400V±15%
-
30A
DIGITAL
22.0kVA
16.2kW
0.74
89%
0.99
31.5A
22.3A
400A
360A
340A
400A
360A
400A
360A
340A
400A
/
360A
3÷400A
61Vdc
61Vdc
IP23S
H
620x240x460mm
22.5kg.
EN 60974-1/EN 60974-10
4x4mm2
5m
TERRA 500 MSE
3x400V±15%
-
40A
DIGITAL
29.7kVA
22.2kW
0.74
90%
0.99
42.1A
29.7A
500A
470A
420A
500A
470A
500A
470A
420A
500A
/
470A
3÷500A
61Vdc
61Vdc
IP23S
H
620x240x460mm
27.3kg.
EN 60974-1/EN 60974-10
4x6mm2
5m
Tabla de contenido
loading

Este manual también es adecuado para:

Böhler terra 400 mseBöhler terra 500 mse

Tabla de contenido