Fisher & Paykel DE27CW1 Instructivo De Instalacion Y Guia Del Usuario página 26

Tabla de contenido
Idiomas disponibles

Idiomas disponibles

Installation instructions
24
Electrical connections (electric models only)
For 4-wire connections by power cords
4-wire power supply cord must have four 10 AWG copper wires and match a 4-wire receptacle
of NMEA Type14-30R. The fourth wire (ground conductor) must be identified by a green cover
and the neutral wire by a white cover.
For 4-wire connections by direct wiring
¾" UL-listed
strain relief
to disconnect
box
10-gauge, 3-wire with
ground wire (Romex)
4 ¼"
1" of wires
stripped of
insulation
NEUTRAL wire
(white or center)
bare ground wire
Fig.22 Wiring 4-wire connections
Strip 4 ¼" of outer covering from end of
cable. Strip insulation back 1".
Shape ends of wire
into a hook.

Capítulos

Tabla de contenido
loading

Productos relacionados para Fisher & Paykel DE27CW1

Este manual también es adecuado para:

Dg27cw1

Tabla de contenido