RESET

General:
The RESET button is located
in the control unit beneath the
housing cover between the two
indicator LEDs. Using a pointed
instrument, the button can be
pressed through the top of the
housing.
Sequence:
Both LEDs go off when the but-
ton is pressed. After 1 sec. the
red LED begins to flash. After another
3 sec. it glows red continuously.
Total RESET (long RESET):
If the RESET button is pressed for longer than 4 sec. a total RESET takes
place. This resets all the configuration data (basic settings) and cancels all
data (including user data).
 Release the RESET button when the red LED has stopped flashing.
Simple RESET (short RESET):
If the RESET button is pressed for longer than 1 sec. but less than 4 sec. a
simple RESET takes place. This resets only the project code.
 Release the RESET button while the red LED is flashing.
Processor RESET:
If the RESET button is pressed for less than 1 sec. a processor RESET
takes place. This is the equivalent of switching the supply voltage off and on
again. No data are cancelled or reset.
 Release the RESET button before the red LED flashes.