• It must be disposed of properly.
• Make the appliance unusable before scrapping.
INSTRUCTIONS FOR INSTALLATION
REMINDERS FOR THE INSTALLER
The manufacturer will not be liable for any damage or in-
jury resulting from failure to observe the following rules
• Read this manual carefully. It provides important information
for safe installation, use and maintenance of the appliance.
• Installation, conversion to a different type of gas and applian-
ce maintenance must be carried out by qualified technicians
authorized by the manufacturer, in compliance with current
safety standards and the instructions in this manual.
• Identify the specific appliance model. The model number is
detailed on the packing and on the appliance data plate.
• The appliance must be installed in a well-ventilated room.
• Do not obstruct any air vents or drains present on the ap-
pliance.
• Do not tamper with appliance components.
5 REFERENCE STANDARDS AND LAWS
Install the appliance in compliance with current safety stan-
dards.
Install the appliance in compliance with the prescriptions of
EN1717 and the water pollution regulations in force in your
country.
6 UNPACKING
Check the state of the packing and in the event of damage, ask
the delivery person to inspect the goods.
• Remove the packing
• Remove the protective film from the external panels. Use a
suitable solvent to remove any residual adhesive from the
panels
7 POSITIONING
• The overall dimensions of the appliance and the position of
connections are given on the installation diagram at the start
of this manual.
• The appliance can be installed singly or in combination with
other appliances in the same product range.
• The appliance is not suitable for integrated installation.
• Position the appliance at least 10 cm from adjacent walls.
This distance can be reduced in the presence of non-combu-
stible walls or heat-insulated walls.
• Level the appliance by means of the height-adjustable feet.
7.1 APPLIANCE ASSEMBLY WITH BASE, BRIDGE, AND
CANTILEVER SOLUTIONS
Follow the instructions provided with the type of support utili-
zed.
7.2 FIXING THE APPLIANCE TO THE FLOOR
Appliances of 40cms in width installed alone must be fixed to
the floor. Use the flanged feet provided.
7.3 JOINING APPLIANCES TOGETHER IN LINE
• Pull out the control knobs , remove control panel.
• Place the appliances side by side and adjust the tops to the
same height.
• Unite the appliances using the screws.
8 FUMES EXHAUST SYSTEM
Create a fumes exhaust system based on the "Type" of ap-
pliance.The "Type" is stated on the appliance data plate.
8.1 APPLIANCE TYPE "A1"
• Position the "A1" type appliance below an extractor hood to
ensure smoke and fumes generated by cooking are removed
8.2 APPLIANCE TYPE "B21"
• Position the "B21" type appliance below an extractor hood
8.3 APPLIANCE TYPE "B11"
• Fit the "B11" type appliance with a suitable flue, available
from the appliance manufacturer Follow the assembly in-
structions provided with the flue.
• Connect the flue to a 150/155 mm diameter hose, heat resi-
stant to 300°C.
• Vent to the outside or into an efficient flue. The hose length
must not exceed 3 metres.
9 CONNECTIONS
The position and dimensions of connections are given in the
installation diagram at the start of this manual.
9.1 CONNECTION TO THE GAS SUPPLY
Check the compatibility of the gas supply. Check the details
given on the decals on the packing and on the appliance.Con-
vert the appliance to the local gas type, if necessary. Follow the
instructions in the next paragraph "Conversion to a different
type of gas".
On top appliances a rear connection is also available. Remove
the plug present and screw it tightly onto the front connector.
• A rapid-action gas shut-off valve must be fitted upstream of
the appliance in an easily accessible position.
• Do not use connection pipes having a diameter smaller than
that of the appliance's gas connector.
• Once the appliance has been installed, check for gas leaks at
the connection points.
9.2 ELECTRICAL CONNECTIONS
Check that the appliance is designed to operate at the voltage
and frequency of the power supply present on site. Check the
details given on the appliance data plate.
• At an easily accessible point upline of the appliance, fit an
all-pole disconnect switch of suitable capacity with a contact
breaking distance of at least 3 mm, and a highly sensitive dif-
ferential protection device. The maximum permitted leakage
current is 1 mA/kW.
• A flexible rubber cable with insulation specifications not lower
than type H05 RN-F must be used for connection.
• Connect the power supply cable to the terminal board as
shown in the wiring diagram supplied with the appliance.
• Secure the power supply cable with the cable clamp.
• Protect the power supply cable on the outside of the applian-
ce with a rigid plastic or metal pipe.
9.3 PROTECTIVE EARTH AND EARTH BONDING CON-
NECTIONS
Connect the appliance to an efficient ground circuit. Connect
the earth conductor to the terminal with the symbol
next to the main terminal board.
located