CAME ZG6 Manual De Instrucciones página 9

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 19
Motor torque limiter
To vary the motor torque, move the indi cated faston to one of the four positions:
1=min, 4=max
Operation counter
F
Counts the number of operations displayed with the 8 LED to zero out the count,
position the dip 1 to OFF (if selected to ON) and the dip 3 to ON, press the CH1
and wait for all the LED to turn off. After zeroing out, return the dip 1 to ON (if
selected) and dip 3 to OFF.
Management of the manoeuvre pick-up function
To manage the manoeuvre pick-up function, position the dip 1 and dip 3 to ON; all 8 LED
of the manoeuvre counter will be on (default memorization for G2081 and G2081I); to select
management of manoeuvre pick-up function for G4041 e G4041I barriers, position the dip 1 and
3 to ON and press the CH1 button. The fi rst 4 LEDs will be on. Reposition the dip 3 to OFF and
dip 1 can be left on the ON position, if automatic closure is desired.
The data and information reported in this installation manual are susceptible to change at any time and without obligation on CAME cancelli automatici s.p.a. to notify users.
Led n°1 = 5000 manoeuvres
Led n°2 = 10000 manoeuvres
Led n°3 = 25000 manoeuvres
Led n°4 = 50000 manoeuvres
Led n°5 = 100000 manoeuvres
Led n°6 = 250000 manoeuvres
Led n°7 = 500000 manoeuvres
Led n°8 = 1000000 manoeuvres
F
G2081 - G2081I
G4041 - G4041I
Tabla de contenido
loading

Tabla de contenido