CONVERSION FROM NATURAL GAS TO LPG
To fit the nozzle, proceed as follows:
•
close the gas valve and disconnect the flexible joint (a);
•
disconnect gas valve (f) from the mixer unit (c) loosening the
four fastening screws (g);
•
fit the nozzle for LPG fuel (d) inside the gasket (e).
•
assemble the components, making sure to correctly position the
sealing gaskets (e, f);
•
switch on the appliance once assembling is complete.
Upon ignition, carry out a leak test of the gas circuit and make sure
that oxygen values (O
%) at max. and min. power are within the
2
tolerances shown in the table below.
ONCE THE CONVERSION HAS BEEN CARRIED OUT,
APPLY THE SUPPLIED ADHESIVE PLATE "LPG" ON THE
BURNER NEAR THE RATING PLATE.
O
values set for natural gas and LPG operation
2
Fuel
Natural gas
L.P.G.
9 / 10
0006160031_201307
O
measured with oven at ap-
2
prox. 100° C at Heating Capacity
min
max
5.0% - 0.3
5.0% - 0.3
5.5% - 0.3
5.5% - 0.3