Wagan Tech Power Dome NX 2485 Manual De Usuario página 15

Tabla de contenido
Idiomas disponibles

Idiomas disponibles

User's Manual—Read before using this equipment
INVERTER TROUBLESHOOTING GUIDE
Trouble
Lack of power output
Inverter Power
Indicator is not lit.
Television/Power
Tool will not start
Television
Interference
Static/noise
interference in audio
system
Wagan Tech and wagan.com are trademarks used by Wagan Corporation.
Cause
Power Dome battery
voltage below 10 volts
Excessive current drawn
by appliance being
operated
Inverter fuse blown
Excessive voltage drop
Inverter is overloaded
High surge wattage
requirement to start-up
Picture breaking up
(snow).
Sound system has weak
alternating current
shielding
©2013 Wagan Corporation. All Rights Reserved.
Remedy
Recharge the Power Dome immediately
Reduce load to maximum of 200 watts
1.
Turn OFF the device and inverter
2.
Disconnect device
3.
Turn the inverter ON and run for
a minimum of 2 minutes
4.
Turn OFF inverter, quickly plug
in device to inverter making sure
device is OFF prior to connection
5.
Turn ON the inverter and device
Check and replace if necessary. Be sure
any replacement fuse is the same type
and rating.
Check Power Dome and recharge if
voltage drops below 12 volts.
Reduce load to maximum of 200 watts.
Toggle the On/Off switch in quick
succession five times. If the device does
not start, the device is not compatible with
this type of inverter.
Place the Power Dome as far from the TV,
antenna, and coaxial cable as possible.
TV station may be out or range.
Do not use inverter with low quality audio
AC filtering system.
Replace audio system with high quality
noise filtering
14