DeWalt DCF894 Traducido De Las Instrucciones Originales página 34

Ocultar thumbs Ver también para DCF894:
Tabla de contenido
EnGLIsH

CAUTION: Inspect anvils, detent pins and hog rings prior
to use. Missing or damaged items should be replaced
before use.
Place the switch in the locked off (centre) position or remove
battery pack before changing accessories.
Anvil with Detent Pin (Fig. D)
DCF894
To install an accessory on the anvil, align the hole in the
side of the accessory with the detent pin
Press the accessory on until the detent pin engages in the hole.
Depression of detent pin may be necessary to aid installation of
accessory.
To remove an accessory, depress the detent pin through the
hole and pull the accessory off.
Anvil with Hog Ring (Fig. E)
DCF894H
To install an accessory on the hog ring anvil, firmly push
accessory onto the anvil 
. The hog ring 
 3 
allow the accessory to slide on. After accessory is installed, the
hog ring applies pressure to help provide accessory retention.
To remove an accessory, grasp the accessory and firmly pull
it off.
nOTE: The thru-hole (Fig. E) allows an O-ring with retaining pin
or a 1-piece retaining pin to be used to help secure sockets and
accessories to the tool.
OPERATION
Instructions for Use

WARNING: Always observe the safety instructions and
applicable regulations.

WARNING: To reduce the risk of serious personal
injury, turn tool off and disconnect battery pack
before making any adjustments or removing/
installing attachments or accessories. An accidental
start-up can cause injury.
Proper Hand Position (Fig. F)

WARNING: To reduce the risk of serious personal injury,
ALWAYS use proper hand position as shown.

WARNING: To reduce the risk of serious personal
injury, ALWAYS hold securely in anticipation of a
sudden reaction.
Proper hand position requires one hand on the main handle 
Usage
Your impact tool generates the following maximum torque.
nOTE: Output torque is dependent on the speed selected, with
the highest provided in the Precision Wrench™ mode.
Cat #
Ft.-Lbs.
Low/High/
Precision Wrench™
DCF894, DCF894H
0–150/0–330/0–330
32

1. Place the accessory on the fastener head. Keep the tool
2. Press switch to start operation. Release the switch to stop
on the anvil 
.
 13 
 3 
compresses to
 14 
MAINTENANCE
Your D
over a long period of time with a minimum of maintenance.
Continuous satisfactory operation depends upon proper tool
care and regular cleaning.

The charger and battery pack are not serviceable.
Lubrication
Your power tool requires no additional lubrication.
Cleaning

.
 4 

nm
Low/High/
Precision Wrench™
200/447/447
CAUTION: Ensure fastener and/or system will withstand
the level of torque generated by the tool. Excessive torque
may cause breakage and possible personal injury.
pointed straight at the fastener.
operation. Always check torque with a torque wrench, as
the fastening torque is affected by many factors including
the following:
ʵ Voltage: Low voltage, due to a nearly discharged battery,
will reduce fastening torque.
ʵ Accessory size: Failure to use the correct accessory size
will cause a reduction in fastening torque.
ʵ Bolt Size: Larger bolt diameters generally require higher
fastening torque. Fastening torque will also vary according
to length, grade, and torque coefficient.
ʵ Bolt: Ensure that all threads are free of rust and other
debris to allow proper fastening torque.
ʵ Material: The type of material and surface finish of the
material will affect fastening torque.
ʵ Fastening Time: Longer fasten ing time results in
increased fastening torque. Using a longer fastening
time than recom mended could cause the fasteners to be
overstressed, stripped or damaged.
WALT power tool has been designed to operate
e
WARNING: To reduce the risk of serious personal
injury, turn tool off and disconnect battery pack
before making any adjustments or removing/
installing attachments or accessories. An accidental
start-up can cause injury.
WARNING: Blow dirt and dust out of the main housing
with dry air as often as dirt is seen collecting in and around
the air vents. Wear approved eye protection and approved
dust mask when performing this procedure.
WARNING: Never use solvents or other harsh chemicals
for cleaning the non-metallic parts of the tool. These
chemicals may weaken the materials used in these parts.
Use a cloth dampened only with water and mild soap.
Never let any liquid get inside the tool; never immerse any
part of the tool into a liquid.
Tabla de contenido
loading

Este manual también es adecuado para:

Dcf894hDcf894p2-qwDcf894hnt-xj

Tabla de contenido