ENGLISH
Installation
The fan must be installed according to the air direction label on the fan. Before the start of assembly, examine manually
whether the fan wheel runs freely. Before installation, check the minimum air gap between the blade tip and the housing
according to the following table. During assembly, secure the assembly area. Take precautions for any access by
unauthorized persons. The fan should be installed in a way that makes service and maintenance easy. A wiring diagram is
applied on the inside of the junction box or separately enclosed. Electrical installations must be made by trained and
authorized electrician.
The components shown in the figure are generally pre-installed on fans. For transport purposes and depending on the
models, some of these components may be supplied unassembled and, in this case, they will need to be assembled during
installation.
The mounting bracket MFT, the silencer JSL, the air flow conditioner VJD and the metal mesh JTK must be connected as
shown in the drawing.
The mounting bracket MFT and the silencer JSL must be fixed with nuts, while the air flow conditioner VJD and the metal
mesh JTK must be fixed with self-tapping screws.
Use
Before starting, check the followings; Be sure that foreign objects are removed from fan area and connected duct system,
check connection to the electrical installation, minimum air gap between the tip of the blade and the housing and no noise
appears when starting the fan. If the air gap is correct, switch the device on and off briefly, in order to check the direction
of rotation of the fan. The rotation direction of the fan must match up with the direction of the arrow on the housing of the
fan. If the direction of rotation is wrong, interchange two phases in order to set the correct direction of rotation.
1
2
REFERENCE
1
2
3
3
COMPONENT
QUANTITY
1
JTK
2
MFT
VJD
1
11