Lamp Replacement
1. Switch off the device and pull the plug.
2. Remove the lamp cover by loosening the
2 screws.
3. Loosen the lamp.
4. Replace the lamp with a lamp of the same type
(2 x 1,5 W LED).
Replacement light (dimensions in mm):
LED module
Round lamp
Maximum wattage
2 x 1,5 W
Voltage range
DC 12 V
ILCOS D code
DSR-1.5/65-S-64
TROUBLESHOOTING
Fault
Light on, but motor does
not work.
Light does not work, motor
does not work.
Shake of the body.
Possible Cause
The leaf blocked.
The capacitor damaged.
The motor jammed
bearing damaged.
The internal with of motor
off or a bad smell from the
motor.
Light damaged.
Power cord looses.
The leaf damaged and
causes shaking.
The motor is not tightly
hanged.
The body is not tightly
hanged.
Solution
Get rid of the blocking.
Replace capacitor.
Replace motor.
Replace motor.
Replace lights.
Connect the wires as per
the electric diagram.
Replace the leaf.
Lock the motor tightly.
Fixed the body tightly.
EN
29