4. Calibrate the correct air and water
pressure
Use the Atlas Copco no. 9090 0550 80 pressure
gauge to check the water and air pressure when
the rock drill is running.
Air pressure
Ensure that the compressor can deliver the
required air volume at 4–6 bar at the tool.
High pressure causes rough operation and
damage.
Low pressure results in a slow drilling speed.
Water pressure
The pressure gauge is equipped with a needle
which is pressed into the hose to measure the
pressure inside.
Note! Make sure that the water pressure is at
least 1 bar lower than the air pressure
otherwise the water can enter the impact
mechanism. For example if the air pressure
is 6 bar, the water pressure must be below
5 bar to prevent water entering the impact
mechanism.
12
www.CrowderSupply.com • Toll Free: 888-883-5144
ALF 72D, ALF 72D-1, ALF 67/80D, BMK 62S, BMK 91 RS
© 2010 Atlas Copco Construction Tools AB

Attachment device

An attachment device is needed to couple the
pusher leg to the rock drill.

BBD 94 W Rock drill

Attachment is fitted to the intermediate part of the
rock drill.

RH 656 W rock drill

Attachment is fitted to the rock drill by clamping it
on the side bolts.
|
|