Selecting the Options
1 Auto closing
ON: Once opened, the door closes completely and
automatically, after the time set by the potentiome-
ter Aut.Clos.Timer
OFF: Automatic closing not activated
2 Pre-flash
ON: Before starting the operation of opening or
closing, the flashing light is activated (1.5 sec during
opening, 3 sec during closing)
OFF: Flashing light not activated
3 Wireless programming
ON: Wireless programming of new transmitters
allowed
OFF: Wireless programming not allowed
4 Deadman
ON: Deadman function
OFF: Automatic function. The door closes with the
Safety input configuration. These 4 switches eliminate the bridge between terminals
1 Sec Close
ON The safety input is not used (terminals 17 and 18
closed)
OFF NC contact is used in the safety input (17 and
18)
2 Stop
ON The stop input is not used (terminals 12 and 14
closed)
OFF NC contact in the stop input is used (terminals
12 and 14)
3 Sec 1
ON The input is not used as a contact / closing
safety sensitive edge, neither as a push button nor
as Deadman closing mode (bridging of the terminals
junior D Pro
alternative push button
5 Sec. 1 Close/Edge
ON: The input Sec.1 Close / Edge functions as a safety
sensitive edge (82Kohmios) when closing
OFF: The input Sec.1 Close / Edge functions as an
active photocell when closing
6 Photocells Test
ON: Photocells test not enabled
OFF: Photocells test enabled
7 Channel 2 / Garage Light
ON: The contact between the output terminals 8 and
9 is activated by pressing the button on the stored
channel + 1.
OFF: The output contact between terminals 8 and 9
operates the light of the garage
8 Permanent Light / Blinking
ON: The output of the blinking light (terminals 6 and
7) is activated intermittently
16 and 18).
OFF You use a NC contact / closing safety sensitive
edge in the entrance security as a push button or a
NO contact Deadman closing mode (terminals 16
and 18)
4 Sec 2
ON the contact input / safety sensitive edge opening
(bridging of terminals 12 and 13) is not used
OFF NC contact in the safety opening input is used
(terminals 12 and 13).