2.4 Attaching the bar
On the V-bracket reference bar holder, place
the shortest bar that still spans between
the shaft brackets. Adjust the position on
the rods to a low position. The bar must not
touch any other part than the bar bracket
during rotation of the shaft. Tighten the
V-bracket in place with the two locking
knobs.
Important:
The Reference bar holder has three resting
surfaces beside the magnet. The bar has to
cover all three resting surfaces for a safe
mounting and accurate measurement.
Note on reference bar play:
The reference bar can be moved perpendicularly to the measurement direction.
The flatness tolerances of the resting surfaces helps ensure a sufficient accuracy.
2.5 Mount the measuring unit
Mount the Measuring Unit on the rods at the
moveable side.
Adjust the gap between the inductive
proximity sensors and the reference bar to
approximately 3mm (
/
inch).
1
8
"Sensor status" in the app indicates the
correct distance.
12
SKF TKSA 11