Adi Interface; Electrical Connection - V2 TORQ-D Manual Del Usuario

Ocultar thumbs Ver también para TORQ-D:
Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 82

4.11 - ADI INTERFACE

The ADI (Additional Devices Interface) interface of the control unit
PD13 allows the connection to V2 optional modules.
Refer to V2 catalogue or to the technical sheets to see which
optional modules with ADI interface are available for this control
unit.
m
WARNING: Please read the instructions of each single
module to install the optional modules.
For some devices, it is possible to configure the mode for
interfacing with the control unit; in addition, it is necessary to
enable the interface so that the control unit can process the
signals arriving from the ADI device.
i.Adi
Please refer to the
programming menu to enable the ADI
interface and access the device configuration menu.
ADI devices use the display of the control unit to issue alarms or
display the configuration of the control unit.
The device connected to the Adi interface is able to signal to the
control unit three alarm signals, which are displayed on the
control unit display as follows:
PHOTOCELL ALARMS - the upper segment comes on: the
gate stops moving, when the alarm stops opening restarts.
EDGE ALARM - the lower segment comes on: inverts motion
of the gate for 3 seconds.
STOP ALARM - both segments start flashing: the gate stops
and cannot restart until the alarm stops.
SLAVE - segment steadily lit: it is used by the optional module
SYNCRO to indicate that the control unit is configured as
SLAVE.

4.12 - ELECTRICAL CONNECTION

J1
START - Open command for connecting
traditional devices with N.O. contact
m
WARNING: If you use maintained
command devices (magnetic loop detectors,
timers, presence detectors, etc.) clock mode
must be used (parameter
J2
START P. - Pedestrian open command for
connecting traditional devices with N.O. contact
m
WARNING: If you use maintained
command devices (magnetic loop detectors,
timers, presence detectors, etc.) clock mode
must be used (parameter
J3
STOP command. N.C. contact
J4
Common (-)
J5
Photocell 1. N.C. contact
J6
Photocell 2. N.C. contact
J7
Type 1 edges. N.C. contact
J8
Type 2 edges. N.C. contact
J9
Accessories common (-)
E1
+24Vdc supply for photocells and other
accessories
E2
Accessory power common (-)
E3
+24Vdc supply - photocell/optical edge TX for
functional Test.
Connect power supply cables of photocells
transmitter between terminals E2 and E3
E4 - E5
Warning light or flashing light (24V)
A1
Antenna shield
A2
Antenna
B1 - B2
230V/120V courtesy or flashing lights
L
Power phase 230 VAC
N
Neutral 230 VAC
BATTERY
Battery pack (code 161237)
RECEIVER
Connector for MRx receiver
ADI
ADI Module interface
OVERLOAD It shows that there is an overload on accessories
power supply
M
Motor
LIMIT
Limit sensor
SENSOR
ENCODER
Encoder
24 Vdc
Control unit power supply (+24 VDC)
POWER
SUPPLY
- 38 -
Strt
CLoC
).
=
Strt
CLoC
).
=
Tabla de contenido
loading

Tabla de contenido