Operating Instructions
Operation (Continued)
Failure to install appropriate water / oil
removal equipment may result in damage
to machinery or workpiece.
AMBIENT OPERATING TEMPERATURE
The compressor is designed to operate in an ambient
temperature between 40° F and 100° F. At ambient temperatures
below 40° F, the unit must be heated up to at least 70° F before
start-up.

Maintenance

See Maintenance Schedule on Page 17.
Disconnect, tag and lock out power source then
release all pressure from the system before attempting
to install, service, relocate or perform any maintenance.
In order to maintain efficient operation of the compressor system, check the
oil level before each use. The ASME safety valve should also be checked
daily (see Figure 10). Pull ring on safety valve. Once pressure has been relieved, safety
valve will close. This valve automatically releases air if the tank pressure exceeds the
preset maximum. If air leaks after the ring has been released, or the valve is stuck and
cannot be actuated by the ring, the ASME safety valve must be replaced.
Do not tamper with the ASME safety valve.
TANK
Never attempt to repair or modify a tank! Welding,
drilling or any other modifi cation will weaken the
tank resulting in damage from rupture or explosion. Always replace worn,
cracked or damaged tanks.
Drain liquid from tank daily.
The tank should be carefully inspected at a minimum of once a year. Look for cracks
forming near the welds. If a crack is detected, remove pressure from tank immediately
and replace.
14
www.campbellhausfeld.com
GUARDING
The belt guard provided must be
installed on the unit.
Never operate compressor
without a beltguard. This unit
can start automatically without warning. Personal
injury or property damage could occur from contact with moving
parts.
All moving parts must be guarded. All electrical covers must be
installed before turning on the power.
DRAINING TANK
Condensate must be drained from the tank daily.
Figure 10 - ASME Safety Valve