3. TRANSPORT, PACKAGING AND STORAGE
3.1 Inspection after transport
The check for the absence of damage and the completeness of the device must be carried out upon receipt
of the package. In the event of identification of damage due to transport, refuse or accept the delivered
product only with reservations *. A complaint detailing the defects observed must then be made. The
perception of damage is only possible in the event of a complaint formulated within the prescribed time limits,
ie 24-48 hours at most.
* written on the carrier's delivery papers or digital.
3.2 packaging
The packaging of the device must be kept in case of moving, or for a return to the after-sales service. The
inner and outer packaging must be completely removed before using the device. The standards in force in
your country concerning environmental protection must be observed before destroying the packaging.
3.3. Storage
WARNING
The device can be kept in stock, but only in its original, closed packaging.
Storage can be carried out in accordance with these conditions:
• Storage in a dry and non-humid place
• Sheltered from the sun
• Control of the stock exceeding 2 months (general condition of the device and all the constituent elements)
• No material shaking
• Storage in closed room and not outside.
4. EQUIPMENT CHARACTERISTICS
* Subject to change
Model
Capacity
Electrical data
Oil pan
Temperature
Basket
dimensions
Dimensions
Weight
CFP13
13L
9 900 W / 400 V / 3 NAC
1
50 - 190 ° C
W 210 x D 300 x H 120 mm
(13 liters)
W 330 x D 600 x H 860-920 mm
34 Kg
CFP132
2 x 13L
2 x 9,900 W / 400 V / 3 NAC
2
50 - 190 ° C
2 x W 210 x D 300 x H 120 mm
(2 x 13 liters)
W 660 x D 600 x H 860-920 mm
64 Kg