DOOR OPENING TIME The position of these dipswitches (DOOR TIME) determines the activation time of
the main entrance electric lock
GUARANTEED CONVERSATION TIME The position of the rotary switch (CONV TIME) determines a
guaranteed conversation time, i.e. extends the busy time from the answer onwards.
The busy time is equal to the reply time (max. 60s) added to the guaranteed conversation time.
Pos. 0 = 1 s
Pos. 1 = 10 s
Pos. 4 = 40 s
Pos. 5 = 50 s
Pos. 9 = high level programming
The guaranteed conversation time must be programmed in the same way for all system call
stations.
TYPES OF SYSTEMS
Single-family system
Two-family system
14
Instantaneous
Pos. 2 = 20 s
Pos. 6 = 60 s
Apartment station
CODE = 0
INT = 0
LINE 1
LINE 2
2Voice
power supply
Apartment station
User 1
CODE = 1
INT = 0
Apartment station
User 0
CODE = 0
INT = 0
LINE 1
LINE 2
2Voice
power supply
3 s
6 s
Pos. 3 = 30 s
Pos. 7 e 8 = 70 s
Calling station
ID = 0
AUX dip 1 = OFF (main)
AUX dip 6 = OFF (single-family)
Calling station
ID = 0
AUX dip 1 = OFF (main)
AUX dip 6 = ON (two-family)
9 s