UK
ADVANCED Intellitherm C75 FUNCTIONS
SYSTEM WORKING HOURS
MINIMUM AND MAXIMUM AMBIENT TEMPERATURE ON THE DAY BEFORE
SUMMER - AIR CONDITIONING
TECHNICAL DATA
- In compliance with CEI EN 60730-1 and parts two
- Contact rating: 5 (3)A 250V a.c.
- Micro-disconnection (1BU)
- Software classe A
- Voltage free switching contact
- Temperature control:
- comfort from 2 to 62°C
- saving from 2 to 62°C
- Differential: ± 0.25°C
- Reference thermal gradient: 4°K/h
- OFF mode with optional antifreeze protection (5°C),
To be set by dip switch
- Max ambient temperature T45
Fantini Cosmi reserves the right to introduce whatever make and technical change at any time without prior notice
time when MINIMUM or MAXIMUM temperature values were recorded
4
Moving the switch I to the
to operate the AIR CONDITIONING system.
Use the red knob to adjust the comfort temperature required in the room, saving and
I
antifreeze operating modes will be excluded.
The red sectors on the display ring will therefore indicate the time periods when
the air conditioning system is on, whereas sectors in any other colour indicate when
the system is off.
With Intellitherm C75 the user may verify how many hours
the heating system has worked (relay closed - ON) the day
before and since the last Intellitherm initialisation (i.e.: since
last reset or battery fitting).
S
1
move switch S to
P
2
move switch P to PROG position
working hours on the day before
3
working hours since last initialisation
4
With Intellitherm C75 the user may verify the MINIMUM
and MAXIMUM ambient temperature values reached on
the day before and when these values were recorded
S
1
move switch S to position
MINIMUM temperature and to position
(comfor t) forMAXIMUM temperature
P
2
move switch P to PROG position
MINIMUM or MAXIMUM ambient temperature value
3
SUMMER position will switch the Intellitherm C75
-
double insulation
- Protection degree: IP20
- Pollution degree 2
- Impulsion de tension 4000V
- Power supply: two alkaline AA 1.5V pencil batteries, no
connection to mains
- Battery life: about two years
- Automatic battery charge monitoring and display
indication in the event of low battery charge
- Battery replacement without loosing memorised data
- Switch for summer or winter operating modes
- Reset key to restore standard programs
- Dimensions: 144 x 84 x 31 mm
8
position
(saving) for