Würth 0891 110 500 Traducción Del Manual De Instrucciones De Servicio Original página 15

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 30
Undo the tank by screwing in an anticlockwise
direction.
Fill product into the tank (maximum 1 litre)
Screw the tank in a clockwise direction until tight.
Use of the device
Note
Fill the bottle with no more than one
litre.
Position the detachable tank and tighten in a
clockwise direction (fig. 3 and 4/III).
Set the relevant product (see Section Conven-
tional or water-based product).
Point the device at the surface to be sprayed
from a distance of 10 to 30 cm.
Press the control lever [4].
3 The device sprays.
After use, disconnect the device from the
compressed air supply and clean (see section
Maintenance / Care).
Work setting of the spray nozzle
(fig. V)
Setting the product quantity
Turn the nozzle regulator [3]:
• Clockwise: Product quantity reduces.
• Anticlockwise: Product quantity increases.
Note
Do not exceed the pre-setting. Other-
wise there is a risk that the regulator
will eject forcefully due to the spring
force.
Adjusting product atomisation
Turn air regulator [2]:
— Clockwise: The air passage reduces and atomis-
ation reduces (becomes coarser).
— Anticlockwise: The air passage increases and
atomisation increases (becomes finer).
Attention!
Risk of property damage
The pressure can also cause the product to
flow out and cause the device to stick strongly
together.
¾ Never completely shut the air regulator [2]
during use.
¾ Never completely unscrew the air regulator [2].
Adjusting the pressure of the incom-
ing air
Turn the pressure reducer [WB]:
• Clockwise: Air flow reduces until it is completely
stopped.
• Anticlockwise: Airflow increases (higher con-
sumption).
Combined setting
Combined setting of the nozzle regulator [3] and
the air regulator [2] allows a smooth or coarse
surface to be achieved as desired; and thus a finish
matching the original finish of the part being treated
can be achieved.
Water-based products
Turn the nozzle regulator [3] clockwise to a
maximum 10–12 mm. The nozzle needle is fully
opened and consequently maximum product
flow from the tank is achieved.
Smooth surface setting
Completely open the air vent regulator [WB]
(turn clockwise). During use air flows from the
tank (reducing the pressure available in the tank)
and reduces the product quantity.
If spraying is not taking place, slowly turn the
air vent regulator [WB] anticlockwise until the
desired product quantity is achieved.
Fully open air regulator [2].
Set atomisation using air regulator [2].
Rough surface setting
Slightly close air vent regulator [WB] (anti-
clockwise). As a result, the pressure in the tank
increases and with it the product quantity.
Slightly close air regulator [2] dependent on the
surface.
Set atomisation using air regulator [2].
15
Tabla de contenido
loading

Tabla de contenido