INSTALLATION INSTRUCTIONS (continued)
5. Position the fan housing (A) so the bottom edge of the fan
housing (A) is flush with the ceiling board. Do not flush mount the
fan housing (A) to the bottom of the joist.
6. Attach the end of each of the suspension brackets (C, D, E) to
the ceiling joists using wood screws (AA).
7. Secure suspension bracket (C) to the fan housing (A) using a
machine screw (CC) and the suspension brackets (D,E) to the
fan housing (A) using machine screws (BB).
8. Remove the wiring box cover from the fan housing (A). Pull the
house wires through the hole in the wiring box cover. Using the
quick connectors, connect the house wiring to the wall switch
(F) and fan housing (A). 14 AWG is the smallest conductor that
should be used for branch circuit wiring. Please refer to the
wiring diagram on page 5 to ensure proper wire connections are
made. Carefully push the wire connections into the wiring box
and reattach the wiring box cover.
NOTE: Do not use metal wall plate with the wall switch (F), as it
may cause interference with the fan operation.
CAUTION: The switch included with this ventilation fan requires
a neutral wire connection. If a neutral line is not present, one
must be run by a qualified electrician. If you require assistance,
please call 1-877-319-3757 before attempting switch installation.
CAUTION: This switch is intended to only operate with this bath
fan. Connections to other electrical fixtures are prohibited and
could cause electrical issues.