tESt anD aDJuStMEnt
NOTE: Sensor has a 2 minute warm up period before
it will detect motion. When switching modes wait 2
minutes.
1. Slide the sensor switch to the TEST position.
2. Place the RANGE adjustment in the medium position
(halfway between MIN and MAX position).
ON-TIME
TEST 1 5 OFF
MINUTES
Bottom of Sensor
3. Loosen the clamp screw in the sensor ball joint.
Clamp Screw
4. Walk through the coverage area noting when the lights
turn on. Gently move the sensor head up, down, or
sideways to change the coverage area. Note: Wait 5
to 10 seconds after light turns off to retest.
Aim Sensor Down for
Short Coverage
8 ft.
(2.4 m)
Maximum Range
5. Increase RANGE only as needed. A higher RANGE
setting may cause false triggering and reduce battery
life.
6. Secure the sensor into position by tightening the clamp
screw. Do not overtighten the screw.
7. After dark, loosen the light joint clamps and adjust the
light to cover desired area. Tighten joint clamps when
desired area is covered.
200068-01
Red LED Indicator
RANGE
MIN
MAX
Ball Joint
Aim Sensor Higher for
Long Coverage
70 ft.
(21 m)
Maximum
Coverage Angle
adjustment of Coverage area
The sensor detects "motion" by the movement of heat
(body heat) across the coverage area.However, following
are examples of objects that also produce heat and can
cause the sensor to false trigger:
• Pools of Water
• Dryer Vents
• Heating Vents
If you suspect that a heat source of this type is falsely
triggering the sensor, try reducing the RANGE or aiming
the sensor away from the heat source in question.
Note: The detector is less sensitive to motion directly
towards it and more sensitive to across motion.
Motion
Least Sensitive
Place the sensor switch in the 1 or 5 minute mode for
normal operation. If the light is not needed, put the switch
in the OFF position.
Mode:
On-Time
test
5 Seconds
auto
1 or 5 Minutes
IMPORTANT: To conserve battery power, this light has
an automatic dimming feature when using the 5 minute
setting. After all motion has stopped, the light will remain
full bright for 2
will dim to about 1/3 power for the remainder of the 5
minute timer.
180°
3
• Air Conditioners
• Fenced-In Animals
• Automobile Traffic
Motion
Sensor
Most Sensitive
OPEratIOn
Works:
Day
/
minutes. After 2
/
minutes, the light
1
1
2
2
Night
x
x
x
Tabla de contenido