Select Blower Option And Install Ductwork; Prepare The Installation - Best PIK33D Instrucciones De Instalación

Ocultar thumbs Ver también para PIK33D:
Tabla de contenido
Idiomas disponibles

Idiomas disponibles

1. SELECT BLOWER OPTION AND INSTALL DUCTWORK

This insert is designed for use with gas or electric outdoor cooking appliances when operated in an outdoor covered patio or
lanai area. As with all electrical appliances, this unit should be protected from the effects of weather as much as possible.
This unit is not designed for use with a charcoal grill.
The insert model PIK33D must be installed with the interior blower P8D, or with the exterior blower model EB12 or EB15 or with
the in-line blower ILB11 only (sold separately). Other blowers cannot be substituted.
If installing in-line blower, refer to instructions packed with in-line blower and follow steps 1 up to 6, 10 up to 13, 15
and up of this manual.
Plan where and how the ductwork will be installed. Access to the top of the hood is preferred for connection of ductwork. As an
alternative, flexible metal ductwork may be used.
Install 10" steel ductwork, elbows and roof or wall cap for the type of blower you are installing. Use round ductwork, with a short
section (about 4' expanded) of flexible metal duct (optional) for attachment to the transition. Use screws to attach flexible metal
duct to the rigid duct. Use 2" duct tape to seal duct joints.
The minimum hood distance above cooktop must not be less than 36". A maximum of 42" above cooktop is highly
recommended for best capture of cooking impurities.
Distances over 42" are at the installer and users discretion.
Roof cap
10" round ducts
with 10" round
metal flex. duct
(optional)
9" x 18" to 10"
round transition
Wall cap
Insert with
interior
blower
36" minimum
above
cooking surface
HH0005A
M
P8D
ODEL
I
B
NTERIOR
LOWER
T
D
YPICAL
UCTWORK

2. PREPARE THE INSTALLATION

When performing installation, servicing or cleaning the unit, it is recommended to wear safety glasses and gloves.
Make sure that the following items are included:
- Insert
- Accessories:
• Transition (9" x 18" to 10" round)
• 3 Baffle filters
• 2 Chrome rings for lights
• 2 Shielded halogen lights (120 V, 50W, type GU10)
• Bag of parts including:
(3) waterproof wire connectors, (2) wire clamps, (8) no. 8 x 3/8" screws, (8) no. 8 x 3/4" screws, (4) no. 10-2" standard screws
(do not use), (2) wall anchors (do not use), (1) barrel nut (do not use) (2) washers (do not use). Discard items not used.
Parts sold separately:
- Interior blower P8D with rough-in plate and flow deviator
- Exterior blower assembly EB12 or EB15 (do not use rough-in plate included with exterior blower)
- In-line blower assembly ILB11 (includes rough-in plate and 2 transitions, do not use the rough-in plate)
- Custom hood liner Model L3336D or L3348D (optional)
- Ductwork (rigid and flexible), elbows, dampers, wall and roof caps. Refer to page 3 for a complete list of venting options and
model numbers.
NOTE: During installation, protect countertop and/or cooktop
All manuals and user guides at all-guides.com
WARNING
!
Exterior
blower
36" minimum
above cooking
surface
HH0042A
M
EB12, EB15
ODEL
E
XTERIOR
T
D
YPICAL
CAUTION
- 4 -
Exterior
blower
10" round duct
with 10" round
metal flex. duct
(optional)
9" x 18" to 10"
round transition
Insert
10" round
metal flex. duct
(optional)
HH0067A
B
LOWER
UCTWORK
Roof cap
10" round duct
In-line blower
Insert
36" minimum
above
cooking surface
M
ILB11
ODEL
I
-
B
N
LINE
LOWER
T
D
YPICAL
UCTWORK
Wall
cap
Tabla de contenido
loading

Tabla de contenido