420010926100 Max Gas 70 - 105- 120 P AB
EN
Connection diagram and control sequence LME22... / LME23...
NT
K1
K2/1
10
12
2
R / W
T
GP
AL
STB
H
Si
L
N
AGK25... PTC resistor
AL
Error message (alarm)
V...
Fuel valve
CPI
Closed Position Indicator
DBR...
Wire link
EK
Lockout reset button (internal)
EK2
Remote lockout reset button
ION
Ionization probe
FS
Flame signal
FSV
Flame signal amplifier
GP
Pressure switch
H
Main switch
HS
Auxiliary contactor, relay
K1...4
Internal relays
KL
Low-fire
LK
Air damper
LKP
Air damper position
Status
Waiting time «tw», other waiting states
Ignition phase, ignition controlled
Operation, flame o.k.
Operation, flame not o.k.
Extraneous light on burner startup
Undervoltage
Fault, alarm
Error code output (refer to «Error code
table»)
Interface diagnostics
Legend: ....... Steady on
ADJUSTING THE AIR PRESSURE SWITCH
The air pressure switch must be adjusted so that an insufficient air flow does not allow
the CO value to exceed 1% in volume. After having adjusted the gas flow and obtained
optimum combustion (CO
pressure switch must be adjusted. Remove the cover with the burner operating, cover
the air intake progressively with a piece of cardboard to obtain a value of CO
(G20-G25)> 13 (G30-G31) and a CO value of less than 5,000 ppm. Adjust the air
pressure switch until the burner shuts down. Remove the cardboard from the air intake
and start up the burner again. Replace the cover.
ADJUSTING THE GAS PRESSURE SWITCH
Adjust the pressure switch to 50% of the rated pressure of the gas used.
RARED PRESSURE:
CONTROL BOXES LME22
μC control
K2/2
K3
K4
3
7
4
5
9
LP
Z
M
BV1
BV2
SA
LP
LR
M
R
SA
STB
Si
t
W
Z
ZV
A
B-B´
C
Color code table for multicolor signal lamp (LED)
Color code
❍ ...................................................................................
● ❍ ● ❍ ● ❍ ● ❍ ● ❍ ● ❍ ● ❍ ● ❍ ● ❍ ● ❍ ● ❍
❑...................................................................................
❑ ❍ ❑ ❍ ❑ ❍ ❑ ❍ ❑ ❍ ❑ ❍ ❑ ❍ ❑ ❍ ❑ ❍ ❑ ❍ ❑ ❍
❑ ▲ ❑ ▲ ❑ ▲ ❑ ▲ ❑ ▲ ❑ ▲ ❑ ▲ ❑ ▲ ❑ ▲ ❑ ▲ ❑ ▲
● ▲ ● ▲ ● ▲ ● ▲ ● ▲ ● ▲ ● ▲ ● ▲ ● ▲ ● ▲ ● ▲
▲...................................................................................
▲ ❍
▲
▲
▲
Red
= 9.5 to 9.8% and a CO value of less than 75 ppm), the air
2
G 20 = 20 mbar
G 25 = 25 mbar
G 30 = 29 mbar
G 31 = 37 mbar
EK
RESET
FSV
6
11
8
1
ION
p a
(LR) BV2
Nur LME23...
12
2
1
br bl
sw
EK
QRC
7101a02e/0606
Air pressure switch
Load controller
Fan motor
Control thermostat / pressurestat
Actuator
Safety limit thermostat
External pre-fuse
Time
Limit thermostat / pressure
switch
Ignition transformer
Pilot gas valve
Start command (switching on
by «R»)
Interval for establishment of
flame
Operating position of burner
▲ ❍
▲ ❍
▲ ❍
▲ ❍
▲ ❍
▲
▲
▲
▲
▲
▲
▲
❑
❍
Green
Off
10
A
B
SB / R
W / GP
AL
I
LK
M
Z
SA
BV1
LP
FS
EK2
t10
t1
t3
t3n
tw
t12
TSA
t11
reached
C-D
Burner operation (generation
of heat)
D
Controlled shutdown by «R»
t1
Prepurge time
t3
Preignition time
t3n
Postignition time
t4
Interval between ignition
«Off» and release of «V2»
t10
Specified time for air pressure
signal
t11
Programmed opening time for
actuator «SA»
t12
Programmed closing time for
actuator «SA»
TSA
Ignition safety time
tw
Waiting time
Flashing yellow
Flashing green
▲ ❍
▲ ❍
▲
▲
▲
Red flicker light
●
Yellow
= 10.8
A
2
B
C
D
B´
C
D
12
10
3
7
9
4
5
6
11
1
8
t4
7101d02/0606
Color
Off
Green
Green-red
Yellow-red
Red
Flashing red