CONNECTION TO THE CHIMNEY - VERSION XILO D 24 MCS W TOP
The boiler is for combustion in a sealed chamber and does not require any special ventilation, it can also be located in
small rooms, lumber-rooms, laboratories. In addition, there are various possibilities for combustion fume evacuation
and external air intake; basically the boiler is designed for two types of fume evacuation/air intake:
● fume evacuation/air intake concentric pipes system,
● fume evacuation/air intake double pipes system.
In this way it is possible, by using suitable kits, to connect the boiler to concentric flues, ventilating flues,
separate flues, etc. Some possible solutions are indicated on page 48.
FUME EVACUATION/AIR INTAKE
Concentric flue pipe, from the roof C32
1
Concentric flue pipe, from the terrace C32
2
3
Double flue pipe from separate flues C42
4
Concentric flue pipe, connected to concentric flues C42
Concentric flue pipe, from an external wall C12
5
6
Double flue pipe from the terrace C52
7
Double flue pipe from single flue C82
Double flue pipe C62
8
8
For positioning and for distances of draught terminals from windows, doors, etc. see regulations in force.