Important! The fitting must be installed, flushed
and tested after the valid norms.
Technical Data
Operating pressure:
Recommended operating pressure: 1 - 5 bars
Test pressure:
Hot water temperature:
Recommended hot water temp.:
Rate of flow by 3 bars:
Hansgrohe mixers can be used together with hydrau-
lically and thermically controlled continuous flow
heaters if the flow pressure is at least 1.5 bars.
Spare parts (see page 3)
1
flange
2
S - unions
3
shut off unit
4
handle for cold water
4.1 screw cover for cold/hot water 96407000
5
handle for hot water
6
aerator cpl. (10)
7
selector assy
8
selector
9
aerator cpl. (10)
6
English
max. 10 bars
16 bars
max. 80° C
65° C
approx. 22 l/mint
94135000
94140000
94142000
12193000
12194000
96406000
96418000
96417000
13485000
Attenzione: la rubinetteria deve essere installata,
pulita e testata secondo le istruzioni riportate!
Dati tecnici
Pressione d'uso:
Pressione d'uso consigliata:
Pressione di prova:
Temperatura dell'acqua calda:
Temp. dell'acqua calda consigliata: 65° C
Portata di erogazione:
I miscelatori Hansgrohe possono venire usati con
caldaie a "bassa pressione" se la pressione di flusso
è almeno di 1,5 bar.
Parti di ricambio (vedi pagg. 3)
1
rosetta
2
raccordi eccentrici
3
cartuccia
4
manopola acqua fredda
4.1 tappino acqua fredda / calda
5
manopola acqua calda
6
rompigetto compl. (10)
7
deviatore compl.
8
deviatore
9
rompigetto compl. (10)
Italiano
max. 10 bar
1 - 5 bar
16 bar
max. 80° C
22 l/min 3 bart
94135000
94140000
94142000
12193000
96407000
12194000
96406000
96418000
96417000
13485000