Safety Notes
Gloves should be worn during installation to prevent
crushing and cutting injuries.
The hot and cold supplies must be of equal pressures.
Assembly (see page 34)
Important! The fitting must be installed, flushed and
tested after the valid norms.
1.
Flush through the supply pipes.
2.
Place the mixer including the sealing washer in
position on the basin / bidet.
3.
Slide the fixation piece including the washer over
the threaded pins and tighten the nuts.
4.
Connect the connecting hose / supply pipes to the
isolation valves; cold right - hot left.
5.
18210000: Connect the pull rod to the pop-up
waste. (see page 35)
Technical Data
This mixer series-produced with EcoSmart®
(flow limiter).
Rate of flow with EcoSmart:
Rate of flow without EcoSmart:
18010000 / 18014000:
18210000:
Operating pressure:
Recommended operating pressure:
Test pressure:
(1 MPa = 10 bar = 147 PSI)
Hot water temperature:
Recommended hot water temp.:
English
7 l/min 0,3MPa
14 l/min 0,3 MPa
12 l/min 0,3 MPa
max. 1 MPa
0,1 – 0,5 MPa
1,6 MPa
max. 80° C
65° C
Hansgrohe mixers can be used together with hydraulically
and thermically controlled continuous flow heaters if the
flow pressure is at least 0,15 MPa.
If the continuous water heater causes any problems or
there is not enough flow of water, the EcoSmart® (5a)
located behind the aerator must be removed.
This mixer is equipped with a flush stream, which enhances
the natural side of the life element water. As this flush
stream does not contain any air, we recommend the use
of Axor Massaud sinks or very deep sinks to prevent
water spray.
Spare parts (see page 3+4)
Special accessories
58085000: special tool set ( order as an extra)
Operation (see page 40)
Cleaning (see page 38)