Comunello CU-230V-2M Instrucciones De Uso Y De Instalacion página 22

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 35
proceed as follows: ensure you have enabled Extended Menu 2 and then
press the SEL key to select blinking LED L3 and press the SET key: LED L3
becomes steady on and programming will be completed.
Repeat the procedure if you want to restore the initial configuration.
4. HOLD-TO-RUN:
The control unit provides the opportunity to set the "Hold-to-Run" function.
If you wish to enable the function, proceed as follows: ensure you have
enabled Extended Menu 2 and then use the SEL key to select blinking LED
L4 and press the SET key; at the same time LED L4 becomes steady on
and the operation will be completed.
With this function enabled using either the remotes or the Pushbuttons to
operate the gate, the following operation will be obtained: the command
must be maintained constantly to move the gate. When the command is
released movement will stop immediately. Repeat the procedure if you want
to restore the previous configuration.
5. FOLLOW ME
The control unit allows the "Follow me" function to be configured;
programmable only if a Pause Time has already been set, this function
reduces the Pause Time to 5 seconds after freeing the SAFE1 photocells,
meaning the gate re-closes 5 seconds after transit of the user. To activate
this function proceed as follows: ensure you have enabled Extended
Menu 2 and then press the SELECT key to select blinking LED L5 and
then press the SET key: LED L5 becomes steady on and programming
will be completed. Repeat the procedure if you want to restore the
previous configuration.
6. FLASHING LIGHT OPERATION
The control unit is factory set with Flashing Light operation during Pause
Time disabled. If you want to enable this function, proceed as follows: make
sure you have enabled Extended Menu 2, press the SELECT key to select
blinking LED L6 and then press the SET key: LED L6 becomes steady
on programming will be completed. Repeat the procedure if you want to
restore the previous configuration.
7. ALWAYS CLOSE FUNCTION
The control unit provides the facility to set "Always Close" operation: this
function, which is programmable only if a Pause Time has already been
programmed, is activated after a power loss; if the gate open condition
is confirmed a closing movement is started automatically, preceded by
5 seconds of preflashing. If you wish to enable the function, proceed as
follows: ensure you have enabled Extended Menu 2 and then use the SEL
key to select blinking LED L7 and press the SET key; at the same time LED
L7 becomes steady on and the operation will be completed. Repeat the
procedure if you want to restore the previous configuration.
RESET
If it becomes necessary to reset the control unit to restore the factory
settings, press the SELECT and SET keys together; this will cause all the
RED indicator LEDs to light simultaneously followed immediately by the
control unit switching off.
DIAGNOSTICS
Photocell Test:
The control unit is prearranged for connection of safety devices in
compliance with standard EN 12453 point 5.1.1.6. At each operating
cycle a functional test of the connected photocell is performed. In the case
of an open circuit and/or malfunctioning of the photocell, the control unit
does not enable movement of the gate and visually signals the test failed
condition by causing all the indicator LEDs to blink simultaneously. As soon
as correct operation of the photocell is restored,the control unit is ready for
normal use. This operating mode guarantees failure mode monitoring in
compliance with EN 954-1 Category 2.
Commands input test:
In correspondence with each low voltage command input the control unit
is equipped with an indicator LED so that the status of the input can be
checked at a glance.
Operating logic: LED on input closed, LED off input open.
WARRANTY
Fratelli Comunello SpA provides a warranty for 24 months for the correct
22
COMUNELLO ®Copyright 2014 - All right reserved
functioning of the actuators from the date of manufacture, provided that the
performance specications indicated in the product instruction manuals are
respected. Free of charge repair and replacement of components that are
found to be faulty according to the indisputable judgment of the company's
technical staff shall be guaranteed at the sole discretion of Fratelli Comunello
Spa, and so excluding any claim for damages made by others. Warranty
material shall be returned to Fratelli Comunello S.p.a. headquarters carriage
paid and will then be shipped to the customer carriage unpaid. The material
found to be faulty and returned to Fratelli Comunello S.p.a. shall remain
property of the Seller. Any cost resulting from any work needed to repair
the defect or to replace the material shall be charged to the Buyer. No
compensation shall be allowed for the period of device inactivity. Work under
warranty does not prolong the warranty period. The defect of the product
shall be reported by the Buyer within 8 (eight) days from its discovery or
from the date of delivery of the goods, under penalty of invalidation of the
warranty. Such claim shall be notied in writing.
Warranty does not cover:
Any product defect or damage that may have been incurred during
transport; any defect or damage arising from any fault and/or from neglect,
inadequacy and misuse of the electrical wiring in the Buyer's property; any
defect or damage caused by any repairs carried out by non authorised
personnel or by incorrect use/installation (with reference to this, system
maintenance is recommended every 6 months) or if not original spare parts
are used; any defect caused by chemicals or atmospheric conditions. The
warranty does not cover any cost neither for consumable materials nor for
alleged defects or convenient surveys.
Product Features Fratelli Comunello SpA products are subjected to
continue changes and improvements; their technical features and image
may therefore change without previous notice.
Competent court
Since the contract of sale is conrmed by an Order Conrmation drawn up
in Rosà, any such dispute shall be settled by the laws of Italy and by the
court of Vicenza (VI).
Tabla de contenido
loading

Tabla de contenido