TECHNICAL SPECIFICATIONS

Power supply:
Flashing light output:
Operator outputs:
Electric lock output:
Photocells power supply:
LV safeties and controls:
Working temperature:
Radio receiver:
Transmitters:
Max TX codes stored in memory: 120 (CODE o CODE PED)
Board dimensions:

PRELIMINARY CHECKS

• Check that the product in the pack is intact and in good condition.
• Check that the place of installation is suitable and in compliance with the
minimum dimensions shown in FIG. 1.
INSTALLATION
• Drill the box in the four corners and then fix the photocells to the wall
(FIG. 2).
• Drill a hole in the underside of the box for the cable inlet. (FIG. 3). The
use of cable glands is recommended.
CONNECTIONS
CN1:
L:
230 V~ line input (phase).
N:
230 V~ line input (neutral).
OPEN1:
Operator 1 opening output.
COM1:
Operator 1 output common.
CLOSE1:
Operator 1 closing output.
OPEN2:
Operator 2 opening output.
COM2:
Operator 2 output common.
CLOSE2:
Operator 2 closing output.
CN2:
ELS:
Voltage-free contact Electric Lock output.
ELS:
Voltage-free contact Electric Lock output.
LAMP+:
Flashing light output (24 V~ 4W max).
FOTO+:
Photocells Control and Power Supply (24V~ 5W max).
GND:
Common power supply (GND).
SAFE2:
Safety Device 2 Input (NC).
SAFE1:
Safety Device 1 Input (NC).
GND:
Common GND input.
PED:
Pedestrian Pushbutton Input (NO).
PP:
Open/Close command Pushbutton input (NO).
ANT:
Antenna Ground Input.
ANT+:
Antenna Hot pole input.
TRANSFORMER CONNECTIONS
CN3 1st:
1: 230 V~ Transformer Primary Winding Input.
2: 230 V~ Transformer Primary Winding Input.
CN4 2nd:
1: Transformer SEC 1 Output 12.5V 0.17A no-load voltages.
2: Transformer SEC 1 Output 12.5V 0.17A no-load voltages.
3: Transformer SEC 2 Output 24.5V 0.4A no-load voltages.
4: Transformer SEC 2 Output 24.5V 0.4A no-load voltages.

FUNCTIONAL CHARACTERISTICS

AUTOMATIC OPERATION:
When either the remote or the low voltage pushbutton panel is used to
control the gate, operation is as follows:
the first command opens the gate until motor time elapses or until the
gate reaches its opening limit position; the second command closes the
gate; if another command is transmitted before motor time has elapsed
or before one of the two limit stops has been reached, the control unit
reverses the movement direction during both opening and closing.
STEP-BY-STEP OPERATION:
When either the remote or the low voltage control pushbuttons are used to
control the gate, operation is as follows:
the first command opens the gate until motor time or until the gate
reaches its opening limit position; the second command closes the gate;
230 V~ 50Hz 1600W max.
24 V~ 4W max.
230 V~ 2 x 500 W max.
Voltage-free contact (24V 5A max.)
24 V~ 5 W max.
24 Vcc
-20 ÷ 55 °C
433 Mhz
18 Bit o Rolling Code
100x105 mm
if another command is transmitted before motor time has elapsed or
before one of the limit stops has been reached, the control unit stops the
movement. Another command causes the gate to start moving again in the
opposite direction.
Step-by-step 1 operations:
When either the remote or the low voltage control pushbuttons are used to
control the gate, operation is as follows:
the first command opens the gate until motor time or until the gate
reaches its opening limit position; the second command closes the gate;
if another command is transmitted before motor time has elapsed or
before one of the limit stops has been reached, the control unit stops the
movement during both opening and closing. Another command causes the
gate to start moving again in the opposite direction.
AUTOMATIC CLOSING:
The control unit can be set up to close the gate automatically without
sending any additional commands. The selection of this type of operation is
described in Pause time programming mode.
PHOTOCELLS:
Photocells can be powered by and connected to the control unit in
accordance with directive EN 12453.
DS1 input (NC)
Tripping of the photocells during opening is disregarded, while during
closing it causes reversal of the direction of movement.
DS2 input (NC)
Tripping during opening causes momentary stopping of the gate; once the
safety is freed the control unit resumes the opening movement. Tripping
during closing causes reversal of the direction of movement. To allow
operation in compliance with EN 13849-1 Category 2 a photocell test is
performed before each movement. The control unit enables the movement
only if the test is passed; if it is not, the control unit inhibits all movements
and an alarm condition is signalled by blinking of all the programming LEDs
on transmission of each command.
OPERATOR FORCE ADJUSTMENT (FORCE):
The electronic control unit is equipped with a "FORCE" trimmer for
adjustment of the force delivered by the operators, completely managed by
the microprocessor. Adjustment can be performed in a range of between
50% and 100% of maximum force. Initial starting torque can be set for each
movement by feeding the operators at full power for 2 seconds, even if
operator force control is enabled. Note: initial starting torque is disabled
automatically if the Soft Start function is enabled.
IMPORTANT: If the "FORCE" trimmer is adjusted the learning
procedure must be repeated because the movement and
deceleration times may change.
DECELERATION (SLOW):
The operators deceleration function is used on gates to prevent the moving
leaves from slamming at speed into the limit stops at the end of the opening
and closing strokes. During Motor Time programming (see Main menu) the
control unit also allows programming of deceleration in the desired positions
(before total opening and closing). If the "Automatic Programming" function
is used (see extended menu 1) it is still possible to include a deceleration
stage only for the first 4 seconds of the movement.
OPERATION WITH TIMER:
The control unit allows a timer to be connected in place of the open – close
pushbutton. E.g.: at 08.00 am the timer closes the contact and the control
unit commands an opening movement; at 06.00 pm the timer opens the
contact and the control unit commands a closing movement. From 08.00
am – 06.00 pm at the end of the opening cycle the control unit disables the
flashing light, automatic closing and the remotes.
ELECTRIC LOCK CONTROL OUTPUT:
The control unit features a voltage-free output contact to power an electric
lock. The contact is closed at each initial opening movement for a period
of 2 seconds.