Adjustment Instructions
1
Safety Instructions
1.1 Power supply must be cut off when replacing or welding any component or inserting / pulling out
connective lines;
1.2 Anti-electrostatic measures must be carried out during the whole producing processes!
a)
Do not touch IC by hands at will;
b)
Use anti-electrostatic iron;
c)
Welder must wear anti-electrostatic glove;
1.3 Replacing any component with special safety requirement must refer to component list without
changing its specification and model at will.
1.4 Power supply voltage must be 120 V±10%, or 220 V would burn out power board.
2
Adjustment Equipments
VG-848 (YPbPr, VGA signal generator)
DVD (HDMI signal generator)
CA-210
3
Adjustment Processes
3.1 Power voltage test
According to the wiring diagram '92XXMF7001JL' or '92XXMF7501JL', connect power board
assembly, data processing assembly, IR/Key board assembly, backlight board assembly correctly,
supply with power, press button standby to power on the TV set.
3.1.1 Model LC-37/39/42/46MFXX
a) Test voltage of X504 each pin on power board in turn shown as Table 1:
X504
Pin 1、2
3、4
Min. (V)
11.3
0
Typical(V)
12.0
0
Max. (V)
12.6
0
b) Test voltage of X505 each pin on power board in turn shown as Table 2:
X505
Min. (V)
Typical(V)
Max. (V)
All manuals and user guides at all-guides.com
Aligment Instructions
Table 1 Voltage of X504 each pin
5、6
7、8
11.3
0
12.0
0
12.6
0
Table 2 Voltage of X505 each pin
Pin 1
2
3.25
4.85
3.30
5.0
3.30
5.35
9
10
11
2.85
4.85
4.85
3.00
5.00
5.00
3.15
5.35
5.35
3~7
0
0
0
12
13
3.25
4.85
3.30
5.00
3.30
5.35
8~12
23.8
24.0
25.2