B
INSTALLATION
G
WARNING
Before using the air conditioner it should be left in an upright position
for at least 2 hours.
This unit is portable and can easily be moved from one room to another. In doing
so keep this in mind:
1
Ensure that the unit is positioned upright and on a level surface.
2
Place the loose filters in the filter holder.
•
Take the filter holder out of the air conditioner
•
Open the filter holder and place the active carbon filter (black) and 3M
HAF filter (white) in the filter holder.
•
Place the filter fixing component back in the holder.
•
Place the filter holder back in the air conditioner.
3
Do not operate the unit inside the bathroom, shower, or in any other very
humid environment.
4
Please keep a distance of 50 cm between the unit and the wall or other
objects to ensure proper air circulation.
5
Insert both ends of the air exhaust hose J in the round connectors 9. Fasten
the connectors by turning them clockwise onto the hose.
6
Insert one round connector 9 in the backside of the unit 7. Fasten the other
connector 9 to the window air outlet K.
7 Attach the hose connector K to air outlet 7 at the back of the unit. Lead the
hose connector K outside and close the gap with the foam components
supplied. These may have to be cut to size.
8 Keep windows and outside doors closed as much as possible in order to
prevent the inflow of exterior air. The air that is intended to enter the room
(specifically during the use of a single hose) in order to allow the airconditioner
to function correctly must always be as cool as possible. Leading this air
through a passage or adjacent room increases the comfort level.
G
IMPORTANT
The flexible air exhaust hose can be stretched to a length of approximately
1500 mm. The length of these hose(s) was calculated on the basis of the
capacity of the device. The use of other hoses or extensions may cause
faults in the device. The air must be able to flow unhindered. If this is not
possible this may lead to overheating or water condensation in the air
exhaust hose. This is why you must ensure that there are no kinks or sharp
corners in the air hose(s). To obtain an optimum result, the air hoses must
be kept shorter than 1 metre while the airconditioner is in use.
TM
4