Hansgrohe Ecostat 1001 13243000 Manual Del Usuario página 7

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 9
Assembly
1. Flush through the supply pipes.
2. Mount the ball S - unions.
Hot water connection left hand, cold water
connection on the right hand side.
3. Screw the escutcheons down the wall.
4. Fasten the mixer using ball union nuts, align and
tighten it.
The S - unions enable inaccuracies in the wall.
Large differences in pressure between the hot and cold
water supply should be balanced.
Adjustment
Correction is necessary if the temperature measured
at the take off point differs from the temperature set
on the scale. To adjust please see page 11.
Operation
The mixer is operated by turning the handle on the
left hand side. The green knob limits the rate of flow
to approx. 10 l/min. If a higher water consumtion is
required press the ECOSTOP button and turn
handle further.
The temperature is selected by turning the
graduated handle on the right side. The flow of the
bath mixer can be changed from tub to shower
function by simply pulling the diverter knob located
at the top of the outlet.
When the water is shut off the flow returns
automatically to the bath function.
Temperature limitation
The temperature is limited by the safety check to 38°
C (100° F). If a higher temperature is required, it is
possible to override the safety stop by depressing
the safety button.
6
English
To garantee a smooth running of the thermoelent, it
is necessary from time to time to turn the thermostat
from total hot to total cold.
The mixer is equipped with non return valves and
filters. If the water flow drops the non return valves
need to be cleaned. For that purpous the mixer has
to be removed from the wall. The filters are located
in the connection pieces underneath the connecting
nuts.
Attention!
The non return valves must be checked once a year.
Using the Ecostat in conjunction with
combination boilers.
When using the Ecostat with combination boilers,
the Ecostop ring "A" has to be removed.
If fitting a hand shower remove the water limiter
from the shower. (Please see page 12)
Technical Data
Operating pressure:
Recommended operating pressure:
Test pressure:
Hot water temperature:
Recommended hot water temp.:
Rate of flow by 3 bars:
anti-pollution function
Spare parts
1
thermoelement
2
shut off unit
3
knob for thermoelement
4
knob for shut off unit
5
mousseur cpl.
6
spout cpl.
7
diverter knob
8
selector cpl.
9
non return valve
10 non return valve DW 15
11 filter
12 escutcheon
13 ball s-unions
14 safety set for temperature control
15 safety set for flow control
max. 10 bars
1 - 5 bars
16 bars
max. 80° C
65° C
20 l/min
94282000
94149000
96127000
96218000
13485000
92440000
94102000
94103000
96737000
94074000
95039000
94135000
94140000
95041000
95042000
Tabla de contenido
loading

Este manual también es adecuado para:

Ecostat 1001 13263000Ecostat 1001 13262000

Tabla de contenido