General Information
CONTROL PANEL
(Figures 3 and 3A)
13. LOW OIL LEVEL LED (yellow): Lights up when oil level is
below safe operating level and the engine shuts down..
14. OVERLOAD LED (red): This LED indicates a system overload.
This LED should be used in conjunction with the READY LED
which will flash an error code, see No. 15.
15. READY LED (green): Indicates output from the generator
unless there is a low oil or overload condition. In the event of
a system overload the Ready LED will provide an indication
of the overload condition. The indication consists of a series
of flashes separated by a pause. These indications are as
follows:
1 Flash = Low Voltage. The unit has been overloaded to the
point where the output voltage has dropped to less
than 100V AC.
2 Flashes = High Temperature of the Inverter System. The
unit has been overloaded to the point where the
internal temperature of the inverter has exceeded
212° F.
3 Flashes = Overload. The unit has been overloaded to
the point that the output power required has
exceeded 110% of rated power.
4 Flashes = Short Circuit. This indicates the unit's output has
been short circuited by the load connected to it.
16. 12 VDC Plug: Connection for re-charging 12VDC automotive-
style batteries while generator is in operation (1400, 1600 and
2000 only).
17. EcoMode Switch: This switch slows the engine speed when
the load is reduced to save fuel and engine wear.
18. 12 VDC Circuit Breaker: Overload protection for the 12 VDC
charging system (1400, 1600 and 2000 only).
19. Ground (Earth) Connection Lug: Grounding point for the
generator; consult state and local electrical codes before use
(floating ground).
20. 120 VAC Receptacles: Two (2) receptacles for connecting
electrical devices.
Do not exceed the rated output of the generator.