ELECTRICAL HOOK UP
Your appliance conforms to the European Directives 2006/95/EC (Low Voltage Directive)
and 2004/108/EC (Electromagnetic Compatibility)".
When you install the appliance and carry out maintenance, it must be unplugged from the
power source or the fuses must be disengaged or removed. Electrical hook up must be carried
out before the appliance is installed in its position.
Check that:
- the power source is sufficient,
- power cords are in good condition,
- the diameter of the cables conforms to installation regulations.
- MOUNTING THE HOOD
Installation must conform to the regulations in force regarding the ventilation of
enclosed environments. In France, these regulations are container in the DTU 61.1 of the
CSTB. In particular, discharged air must not be channelled into a conduit used for exhaust
discharge or discharge from devices that operate with gas or other combustible materi-
als. The use of unused conduits is not permissible without the approval of a qualified
technician. The minimum distance between the hob surface and the lowest part of the
hood must be 70 cm. IF the instructions for the cooker installed under the hood require
an even greater distance, this must take precedence.
20