Becken BAC4255 Manual Del Usuario página 13

Tabla de contenido
Idiomas disponibles

Idiomas disponibles

The maximum number of pieces of equipment permitted to be
stored together will be determined by local regulations.
• Information on servicing
1. Area checks
Prior to beginning work on systems containing flammable refrigerants,
safety checks are necessary to ensure that the risk of ignition is
minimised. For repair to the refrigerating system, the following
precautions shall be complied with prior to conducting work on the
system.
2. Work procedure
Works shall be undertaken under a controlled procedure so as to
minimise the risk of a flammable gas or vapour being present while the
work is being performed.
3. General work area
All maintenance staff and others working in the local area shall be
instructed on the nature of work being carried out. Work in confined
spaces shall be avoided. The area around the work space shall be
sectioned off. Ensure that the conditions within the area have been
made safe by control of flammable material.
4. Checking for presence of refrigerant
The area shall be checked with an appropriate refrigerant detector
prior to and during work, to ensure the technician is aware of
potentially flammable atmospheres. Ensure that the leak detection
equipment being used is suitable for use with flammable refrigerants,
i.e. no sparking, adequately sealed or intrinsically safe.
5. Presence of fire extinguisher
If any hot work is to be conducted on the refrigeration equipment or
any associated parts, appropriate fire extinguishing equipment shall be
available on hand. Have a dry power or CO
the charging area.
Portable air conditioner | Aire acondicionado portátil | Ar Condicionado Portátil
AF_Manual_AC_12000BTU_BAC4255_BAC4255N.indd 13
fire extinguisher next to
2
EN
13
21/01/2019 10:24
Tabla de contenido

Solución de problemas

loading

Este manual también es adecuado para:

Bac4255n

Tabla de contenido