Electrical Connection - Unitor HPC 30/1 Manual Del Usuario

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 32
agents or chemicals may adversely affect the safety of the machine.
• Risk of explosion – Do not spray flammable liquids. Do not clean deli-
cate parts made of rubber, fabric, etc. with the jet nozzle. Keep some
distance between the jet nozzle and surface in order to prevent the sur-
face from damage.
4 Transport
For safe transport in and on vehicles we recommend to prevent the equip-
ment from sliding and tilting by fixing it with belts. For transport and storage
at temperatures around or below 0°C, anti-freeze should be drawn into the
pump beforehand (Please refer to Operating Instructions).
5 Water connection
This machine is only allowed to be connected with the potable water mains,
when an appropriate backflow preventer has been installed, Type BA, ac-
cording to EN 60335-2-79.
The length of the hose between the backflow preventer and the machine
must be at least 12 meters (min diameter 3/4 inch) to absorb possible pres-
sure peaks. Operation by suction (for example from a rainwater vessel) is
carried out without backflow preventer.
WARNING
• Water that has flowed through backflow preventer and high pressure
washer is considered to be non-potable.

6 Electrical connection

The electric supply connection shall be made by a qualified electrician and
comply with IEC 60364-1. It is recommended that the electric supply to this
machine should include either a residual current device that will interrupt
the supply if the leakage current to earth exceeds 30 mA for 30 ms or a de-
vice that will prove the earth circuit.
Switching on the cleaner may cause voltage fluctuations. Voltage fluctu-
ations should not occur if the impedance at the transfer point is less than
0.15 Ohm. If in doubt ask your local electricity supplier.
10
All manuals and user guides at all-guides.com
Original instruction
Tabla de contenido
loading

Tabla de contenido