Manufacturer's Warranty - Forch STARTIUM 680E Manual De Instrucciones

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 86
In the event of an overvoltage fault, the device protects itself. The error-LED lights up
and the display shows "dEF". When the overvoltage is too high an internal fuse protects
the device. This fuse has to be replaced by a service technician of the customer service.
NOTES AND WARNINGS
Risk of explosion: During the charging process explosive gases can be produced.
Always make sure to have a well-ventilated environment. Avoid sparks, flames, hot and
glowing objects in the vicinity of the battery.
Protect the unit against rain and moisture.
If the charger and/or the cables are defective then hand over the charger to the manu-
facturer for repair resp. to a specialised dealer for service works.
The external fuse must be replaced manually.
Never try to charge defective or non-rechargeable batteries.
Adhere to the connection sequence for the device described in this manual.
Product für selective collection (hazardous waste). Never throw the device in the house-
hold waste!
This device is no toy! Protect it from unauthorized use.
Under no circumstances open the device housing on your own. All repair works and
modifications have to be made by the manufacturer's service department, otherwise your
warranty will be void.
Make sure that the main power supply voltage complies with the voltage requirements
printed on the nameplate of the device.
MALFUNCTIONS; CAUSES; REMEDIES
MALFUNCTIONS
The error LED lights up.
The error LED lights up
and the buzzer sounds.
No LED lights up.
In the START ENGINE mode the
display shows
0%. Starting is impossible.
The battery is boiling.

MANUFACTURER'S WARRANTY

The manufacturer's warranty will be performed exclusively for manufacturing or material
defects that are indicated within 12 months after purchase (proof by purchase receipt).
After acknowledgement of the warranty by the manufacturer or his authorized represen-
tative, a free repair or a free replacement of spare parts is carried out in favour of the buyer.
CAUSES
No or bad network contact.
Short-circuit or reverse polarity
of the terminals.
The battery to be loaded is badly damaged.
Error with regard to voltage (12 -24 V)
No battery or battery <1 V.
Display: «BAt HS»
After intense use the heat protection
is active. Display : «th»
Important problem with power supply
The internal fuse has melted.
The ON/OFF-switch is not on ON.
The battery is sulfated, starting is disabled in
order to protect the electronics of the vehicle.
The selection 12V or 24V is wrong.
Short-circuit caused by battery.
REMEDIES
Check the power supply.
(A) Check the condition of the protection fuse.
(B) Do not short-circuit the terminals. Change the
terminal posts
Check with a voltmeter whether both battery posts
are under current. In case the voltage is more than
2,5V per cell, the battery is sulfated or damaged.
Check whether the battery is connected correctly to
12V or 24V.
(A) connect a battery
((B) select the function TIMER in case the battery
voltage is under 1 V.
Wait for 15 min for the device to cool.
Check the power supply.
Send the device to the customer service.
Turn the ON/OFF-switch to ON.
Pre-charging of the battery before a starting process
in the START ENGINE mode is performed.
Check the voltage of the battery and connect
correctly.
The battery cannot be charged, it has to be replaced.