Field
Explanation
Time zone: Can be selected man-
ually.
Set time: Specify a time, if the net-
work time is not available as a ref-
erence.
Units
Select the parameters and units that are to be used
for the device.
Device display
This setting determines the brightness of the
charger's display.
Charging
Grid status
This setting is only visible for the Customer service
user. The information on the grid status presented
here is automatically detected by the device.
Display
Explanation
Mains phases
Number of supply cable phases.
Network type
The set grid is displayed to the
Customer service user.
Maximum
Setting for the maximum charg-
charging cur-
ing current is displayed.
rent
Serves, during setup, to check
the setting made.
Restricted op-
The charging power is reduced
eration
at excessive temperatures.
Grounding monitor
Electric shock, short cir-
DANGER
cuit, fire, explosion
Using the charger without active ground monitoring
can cause electric shocks, short circuits, fires, explo-
sions or burns.
e
The charger must preferably be operated in
grounded power grids.
e
Only deactivate ground monitoring in non-
grounded power grids.
e
Activate ground monitoring in grounded power
grids.
Adjust charging current
If the charging current to the vehicle is too high, the
fuse can be triggered causing the power supply to fail
in the supply area of the fuse.
If an energy manager is connected to the charger,
the overload protection provides monitoring of the
charging current to the charger. If there is no energy
manager available in the home network, you must
stipulate a maximum current for the charger.
The charging current specified here may not exceed
the maximum value of the charging current with
which the electrical installation can be loaded.
The following must be observed when specifying the
maximum charging current:
The Wall Charger Connect may only be con-
nected by an electrician.
g Information on setup is set out in the Porsche Wall
Charger Connect operating instructions.
Information
The charging power must never be set higher than
the maximum available power of the electrical circuit.
Only a qualified electrician may set the maximum
possible charging current during setup.
The charging current setting (reduction of set maxi-
mum value) may be performed by the customer in
the Web Application.
e
If you have any questions on this, contact a
qualified electrician.
Information
If there is a connection to the energy manager, the
value stipulated here is overwritten with the settings
of the energy manager.
b Vehicle cable is connected to the charger.
e
In the Web Application, use the controller to set
a minimum and a maximum for the charging
current.
Service
Displaying device information
This information pertains to the device, e.g. version
number, serial number and host name.
In the event of an error message, this data is required
by the Porsche Service Partner.
Operation