Installation of the 5-way connection element
– The matrix can be quickly and securely connected, locked,
unlocked and cascaded with the following unit with the 5-way
connection element
What to do when...?
Problem
LED of a matrix with integrated power supply
unit does not light up (e. g. for EXR 5016)
Matrix does not switch
Matrix switches, but no matching pictures
appears
Vertical programmes do not work
Picture switch-over is too slow
Internet: http://www.kathrein.de
KATHREIN-Werke KG · Anton-Kathrein-Straße 1–3 · Postfach 10 04 44 · D-83004 Rosenheim · Germany · Telefon (0 80 31) 18 40 · Telefax (0 80 31) 18 43 06
Possible cause
Short-circuit in horizontal circuit
Overload in horizontal circuit
No control signal from the receiver
No control signal from the receiver
Input connections are reversed
Overload in vertical circuit
Short-circuit in vertical circuit
DiSEqC is switched on
Opens the
Opens the
sockets on
sockets on
the left side
the right side
Solution
Check the coaxial cable
Reduce the current load by using an additional power unit
e. g. on the already switched on amplifier
Check if the connection from the receiver to the matrix is
short-circuit free
Check the menu settings of the receiver
Check if the connection from the LNB to the matrix is correct
Locally feed inadmissible users (e. g. in-line amplifier)
Check coaxial cable
Set DiSEqC to "Off" in the menu setting of the receiver
Opens the
sockets on
the left and
right side