Information about this operating manual
Please read the operating instructions and familiarise yourself with the unit prior to using it for the first
time. Adhere to the safety information for the correct and safe use of the unit. Please keep these
operating instructions in a safe place! Also hand over the operating instructions when passing the
unit on to a new owner. Ensure that all work with this unit is only carried out in accordance with these
instructions.
Intended use
The FIAP profiair NANO series, referred to as unit in the following, is a pond and basins aerator. Only
operate the unit with normal pond water at a water temperature between +4 °C and +35 °C. The unit is
suitable to operate in swimming ponds while respecting the national regulations for installers, and in
water basins on patios.
Use other than that intended
Danger to persons can emanate from this unit if it is not used in accordance with the intended use and
in the case of misuse. If used for purposes other than that intended, our warranty and operating permit
will become null and void.
CE Manufacturer's Declaration
We declare conformity in the sense of the EC directive, EMC directive (2004/108/EC) as well as the
low voltage directive (2006/95/EC). The following harmonised standards apply:
EN 55014-1, EN 55014-2, EN 60335-1, EN 60335-2-41, EN 60598-1, EN 60598-2-18, EN 61000-3-2,
EN 61000-3-3, EN 61558-2-6, EN 60598-2-7, EN 61558-1, EN 60825-1
Safety information
FIAP has manufactured this unit to the current state of the art and the valid safety regulations. Despite
of the above, hazards for persons and assets can emanate from this unit if it is used in an improper
manner or not in accordance with its intended use, or if the safety instructions are ignored.
For safety reasons, children and young persons under 16 years of age as well as persons who
cannot recognise possible danger or who are not familiar with these operating instructions, are
not permitted to use the unit!
Please keep these operating instructions in a safe place! Also hand over the operating instructions
when passing the unit on to a new owner. Ensure that all work with this unit is only carried out in
accordance with these instructions.
The combination of water and electricity can lead to danger to life and limb, if the unit is incorrectly
connected or misused.
Attention! Danger of electric shock. Ensure that the cable connection points and their
surroundings are dry.
Do not let the device run dry. Vibrations can irreparably damage the ceramic membrane.
Protect the connection cable when burying to avoid damage. Only use cables approved for outside
use. Ensure that the power connection cable cross section is not smaller than that of the rubber sheath
with the identification H05RN-F. Extension cables must meet DIN VDE 0620. Only use unwound
cables. Electrical installations in garden ponds and swimming ponds must meet the national and
international regulations valid for installers. Compare the electrical data of the supply with those on the
unit type plate. This data must coincide.
Never operate the unit if the cable or housing are defective! Disconnect the power! Do not carry or pull
the unit by the connection cable.
Technische Änderungen vorbehalten. Für Druckfehler übernehmen wir keine Haftung. WEEE-Reg. Nr.: DE78152045
FIAP GmbH, Jakob Oswald Str. 16, 92289 Ursensollen
Tel: 09628 9213 0; Fax: 09628 9213 30;
7
www.fiap.com
FIAP profiair NANO
Never open the unit housing or its attendant components, unless this is explicitly mentioned in the
operating instructions. Always disconnect the power supply of all units located in water and of this unit
prior to performing work on the unit! For your own safety, consult a qualified electrician if you have
questions or encounter problems!
Correct electrical installation
Electrical installations at garden ponds must meet the international and national regulations valid for
installers. Especially adhere to DIN VDE 0100 and DIN VDE 0702. Only use cabes admitted for
external use and meeting DIN VDE 0620. Ensure that the transformer is protected by a rated fault
current of max. 30 mA via a fault current protection device. Only connect the transformer when the
electrical data of the power supply is identical to that on the type plate. Only operate the transformer
when plugged into a correctly fitted socket. For your own safety, consult a qualified electrician when
you have questions or encounter problems.
Safe operation of the unit
Keep socket and power plug dry. Route the power cables so that damage is excluded. Do not carry or
pull the units by the connection cables. The power connection cables cannot be replaced. If the cable
is damaged, the entire unit has to be disposed of. Never run the pump without water! Otherwise the
pump will be destroyed. Never use the pump for fluids other than water. Other fluids could destroy the
unit. Never open the unit or its attendant components, unless this is explicitly mentioned in the
operating instructions. Never carry out technical modifications to the unit. Only use original spare parts
and original accessories for the unit. Only have repairs carried out by authorised customer service
points.
Maintain a safety distance of at least 50 cm from combustible material. Ensure a safe seating. Do not
cover the unit. Danger of fire! Position the unit such that it does not present a hazard for anybody.
Connect the power plug of the pond foger to the socket of the transformer bush.
Installation, connection and alignment
Attention! Dangerous electrical voltage.
Possible consequences: Death or severe injury. For use, install the transformer at a minimum safety
distance of 2 m from the bank. Choose an installation place for the transformer that is splash-water
protected. Also protect the transformer against sun radiation (max. 40 °C).
Start-up
Connection
Connect the unit and the transformer using the two-pole plug. Fasten the plug using the union nut.