▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬ FRY TOP (GAS SUPPLY)
COMBUSTED GAS EXHAUST CONNECTION
Forced exhaust under hood connection
– Place the appliance under the hood (L).
Caution - Precaution
The exhaust system fan electrical con-
trol system must be integrated with the
gas supply system so that the fan turns
on as soon as gas supply is opened.
Danger - Warning
Combustion smoke exhaust must be
connected by personnel with specific
skills, according to current law and us-
ing appropriate and compliant materials
GB
(according to that set by regulation
"UNI-CIG 8723").
RECOMMENDATIONS FOR USE
Make sure the gas mains features correspond to those indicated on the appliance
plate.
Caution - Precaution
Do not use the appliance if the gas mains features do not correspond to those indi-
cated on the specific plate.
If gas mains features do not correspond to those indicated on the specific plate,
have an expert technician with specific skills transform gas.
1 - Pour a small amount of water in the residue tray to facilitate cleaning after use.
2 - Press and rotate knob (B) anti-clockwise (pos. (D)) and at the same time repeatedly
operate piezoelectric switch (A) to turn on burner.
3 - Hold down the knob for about 10 sec. to trigger the thermocouple.
L
- 16 -
English language