19 Specifications

18.2
Troubleshooting the Charger
Fault
LED on Char‐
ger
Battery not being
One LED glows
charged.
red.
The LED fla‐
shes red.
The charger
The LED
does not run a
glows green for
self test.
about 1 second
and then red
for about
1 second.
19 Specifications
19.1

STIHL HSA 26 Shrub Shears

– Approved battery: STIHL AS
– Weight without battery:
– with shrub shear blades: 0.8 kg
– with grass shear blades: 0.7 kg
For battery life see www.stihl.com/battery-life.
19.2
Shrub Shear Blades, Grass
Shear Blades
Shrub shear blades
– Maximum opening: 8 mm
– Tooth spacing: 19 mm
– Cutting length: 200 mm
– Sharpening angle: 30°
Grass shear blades
– Tooth spacing: 16 mm
– Cutting length: 120 mm
– Sharpening angle: 35°
19.3

STIHL AS Battery

– Battery Technology: Lithium-ion
– Voltage: 10.8 V
– Capacity in Ah: see rating label
– Energy content in Wh: see rating label
– Weight in kg: see rating label
19.4
STIHL AL 1 Charger
– Rated voltage: see rating pate
– Frequency: see rating plate
– Rated power: see rating plate
– Charging current: see rating plate
0458-601-9821-B
Cause
The battery is too
warm or too cold.
No electrical contact
between charger and
battery.
There is a malfunction
in the charger.
There is a fault in the
battery.
Electrical contact to
charger was briefly
interrupted.
– Maximum energy content of approved STIHL
AS battery: 12.5 Ah
For charging times see www.stihl.com/charging-
times.
19.5
If an extension cord is used, the cross sectional
area of its conductors must meet the following
minimum requirements – depending on the line
voltage and length of the extension cord:
If rated voltage on the rating label is 220V to
240V:
– Cord length up to 20 m: AWG 15 / 1.5 mm²
– Cord length 20 m up to 50 m: AWG 13 /
2.5 mm²
If rated voltage on the rating label is 100V to
127V:
– Cord length up to 10 m: AWG 14 / 2.0 mm²
– Cord length 10 m up to 30 m: AWG 12 /
3.5 mm²
Remedy
► Leave battery inserted in charger.
Charging starts automatically as soon as
the permitted temperature range is rea‐
ched.
► Remove the battery.
► Clean contacts on charger.
► Insert battery.
► Do not use the charger and contact your
STIHL dealer for assistance.
► Do not use the battery. Consult a STIHL
dealer.
► Disconnect the mains plug from the
power supply.
► Wait for 1 minute.
► Insert the mains plug in a wall outlet.