Guarantee

Malfunction
Hydraulic pump whistles, split-
ting wedge moves jerkily.
Motor becomes very hot.
NOTE
If you encounter any malfunctions that are not listed in this table or that you cannot rectify
yourself, please contact our customer service.
14 GUARANTEE
We will resolve any material or manufacturing faults on the appliance during the legal warranty period
for claims relating to faults, in accordance with our choice either to repair or replace. The legal warranty
period is determined by the legislation of the country in which the appliance was purchased.
Our warranty promise applies only if:
These operating instructions are heeded
The appliance is handled correctly
Original spare parts have been used
The guarantee excludes:
Paint damage that can be attributed to normal wear and tear
Wear parts that are marked with a frame
The guarantee period commences with purchase by the first end user. The date on the proof of pur-
chase is decisive. In the event of a guarantee claim, please take this guarantee declaration and the
original proof of purchase, and contact your dealer or the nearest authorised customer service centre.
This statement does not affect the purchaser's statutory claims for defects against the vendor.

15 EU DECLARATION OF CONFORMITY

We hereby declare that this product in its marketed form conforms to the requirements of the harmon-
ised EU Directives, EU safety standards and the product-specific standards.
Product
Manufacturer
Log splitter
AL-KO Geräte GmbH
Ichenhauser Str. 14
Serial number
D-89359 Kötz
G4032012
Germany
Type
EU directives
LSV 6
2006/42/EC
LSV 7
2014/30/EU
LSV 8
2011/65/EU
442310_a
Cause
Insufficient hydraulic oil
Air in hydraulic circuit
Inadequate cable cross-section
of an extension lead
Missing phase
The warranty becomes void in the case of:
Unauthorised repair attempts
Unauthorised technical modifications
Non-intended use
xxxxxx (x)
Duly authorised person for technical file
Andreas Hedrich
Ichenhauser Str. 14
D-89359 Kötz
Germany
Harmonised standards
EN 60204-1:2006+A1:2009
EN 609:1999+A2:2009
EN 55014-1:2006+A2:2011
Remedy
Top up hydraulic oil.
Loosen vent plug.
Use an extension lead with a
larger cable cross-section.
Have inspected and corrected, if
necessary, by a qualified electri-
cian.
on the spare parts card
EN 55014-2:1997+A2:2008
EN 61000-3-2:2014
EN 61000-3-11:2000
49
Tabla de contenido
loading

Este manual también es adecuado para:

Lsv 7Lsv 8113602113603113601