Safety And Protective Devices; Electrical Connection - AL-KO LSV 6 Manual De Instrucciones

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 120
GB
2.6

Safety and protective devices

Motor protection switch
The motor protection switch switches off the mo-
tor if the log splitter is overloaded. Do not deacti-
vate the function of the motor protection switch.
If the motor protection switch has switched off the
log splitter, proceed as follows:
1. Disconnect the log splitter from the mains.
2. Determine the cause of the overload.
3. Allow the log splitter to cool down for several
minutes, then connect to the mains again.
4. Switch on the log splitter.
Two-hand operation
The splitting wedge travels down only when both
operating arms are actuated simultaneously. This
eliminates the risk of the operator's hands being
in the danger area.
2.7

Electrical connection

WARNING!
Risk of injury from elec-
tric shock
A defective mains cable
can result in serious inju-
ries due to electric shock.
Ensure that the mains
cable is not damaged or
severed.
The maximum permissible cable length must
not be exceeded. A longer cable impairs the
motor power and hence the performance and
function of the log splitter.
Mains cable, mains plug and coupling socket
must be undamaged. A defective mains ca-
ble (e.g. with cracks, cuts, crushed or kinked
points in the insulation) must not be used.
Repairs to the mains cable, mains plug and
coupling socket may only to be carried out by
qualified electricians.
Do not expose plug connectors to moisture.
If the mains cable is damaged, immediately
disconnect it from the mains.
34
Demands on the electrical connection
The mains power supply must be equipped with
protective devices against low voltage, overvolt-
age, overload current (16 A) and an earth leak-
age circuit breaker (max. leakage current 0.03 A).
Further demands on the electrical connection can
be found in the technical data.
Requirements for the mains cable
NOTE
A mains cable is not included in the
scope of supply and must therefore be
purchased separately.
The mains cable must satisfy the following de-
mands:
For LSV 6 and LSV 7:
Suitable for 230 V AC
3 cores (1P + N + PE)
Maximum cable length: 10 m
For LSV 8:
Suitable for 400 V AC
5 cores (3P + N + PE)
Maximum cable length: 10 m
Product Description
LSV 6, LSV 7, LSV 8
Tabla de contenido
loading

Este manual también es adecuado para:

Lsv 7Lsv 8113602113603113601

Tabla de contenido