Installation Of Accessories To The Control Unit - Allmatic BOOMY4 Manual Del Usuario

Operatore irreversibile ambidestro per passi carrai
Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

8. INSTALLATION OF ACCESSORIES TO THE CONTROL UNIT

GND
TX
RX
+24V
+ 24V
NC contact
TX
A
1
2
3
4
5
LED STATUS
LED RADIO

20 21
B
C
Description:
A. Terminal block accessories input and output
B. Radio Module
C. Antenna terminal block
D. J1 - Connector for plug-in led control board
E.
J2 - Connector for battery charger card
F.
J3 - Connector for external radio memory
G. Inputs and Securities Dip Switch
H. Display and buttons
I.
Fuse1 - 10A fuse for motor protection
J.
Fuse2 - 2,5A fuse for accessories protection
K.
Fuse - 2,5A fuse
WARNING!
Please note that PH3 and S3 inputs are exclusively dedicated to the "presence sensor" (the photocell and the magnetic loop that
is close to the automation) and cannot be used for other types of intervention. Like the STOP input, PH3 and S3 are both NORMALLY
CLOSED inputs, so the control unit interrupts its normal operation if at least one of these contacts is open.
18 / 36 - English
Loop
Detector
STOP DRY
CONTACT N.C.
6
7
8
9
10
11 12 13 14 15 16 17
LED STATUS
G
H
J1
LOOP
S3
FLASHING LAMP
24Vac 25W
A
J4
F
J3
FUSE 2
D
E
230V 50Hz
N
PE
L
FUSE
24V
M
K
FUSE 1
I
J
J2
6-1622396 - rev. 3 - 21/09/2021
TRANSFORMER
230V / 23V 50Hz
Tabla de contenido
loading

Tabla de contenido