OUTPUT configuration
This item covers the functions available and associable with Outputs 1 (flash) - 2 - 3 present on the control unit of an automa-
tion. Each output has various functions as described in a table (Table 2, Table 3 etc):
output 1 (flash)
In this output the user can select one of the functions specified in Table 2.
FUNCTION
sca (= gate open indicator)
gate open
gate closed
maintenance indicator light
flashing light
courtesy light
electric lock 1
suction cup 1
radio channel no.1
TABLE 2: OUTPUT CONFIGURATION
DESCRIPTION
The programmed light indicates the operating status of the
control unit.
light off = application in maximum Closing position;
slow flashing = application Opening manoeuvre execution
phase;
quick flashing = application Closing manoeuvre execution
phase;
light permanently on = application in maximum Opening
position.
The programmed light indicates the operating status of the
control unit.
light on = application in maximum Opening position;
light off = application in other positions.
The programmed light indicates the operating status of the
control unit.
light on = application in maximum Closing position;
light off = application in other positions.
The programmed light indicates the count of manoeuvres
completed and therefore the need (or not) for system mainte-
nance operations.
light on for 2 sec at start of Opening manoeuvre = number
of manoeuvres less than 80%;
light flashing during execution of entire manoeuvre = num-
ber of manoeuvres between 80 and 100%;
light always flashing = number of manoeuvres over 100%.
This function enables the flashing light to indicate execution of
a manoeuvre in progress with flashes at regular intervals (0.5
sec ON, 0.5 sec OFF).
This function type is ON/OFF. Important – For safety reasons,
as the light is not controlled by a timer, use of an adequate light,
able to withstand the heat of the light emitted, is recommended.
With this function programmed, when an Opening manoeuvre
is performed the electric lock is activated for a time as set in
the function "electric lock time – output configuration".
With this function programmed, the suction cup is activated
when the application is in the maximum Closing position. Note
– The suction cup is disabled in all other situations.
When the suction cup is disabled, before an Opening manoeu-
vre is started, the time interval as programmed in the function
"suction cup time – output configuration" is activated, which
delays the start of the manoeuvre.
If this radio channel is set for the configuration of output 1
(flash), this channel is activated when a command is set with
the transmitter. It is useful if installing external devices (for
example, an auxiliary light) in the same system to be controlled
with a single transmitter.
WARNING – If this channel is not free on the control unit
receiver, as previously memorised with a command, the con-
trol unit activates exclusively the programmed output when the
channel is activated with the transmitter, ignoring the com-
mand to the motor.
Robus 600-1000 – 15